交流电弧炉的高效供电方案

Malinovskyi Anton, Turkovskyi Volodymyr, Muzychak Andrii, Turkovskyi Yurii
{"title":"交流电弧炉的高效供电方案","authors":"Malinovskyi Anton, Turkovskyi Volodymyr, Muzychak Andrii, Turkovskyi Yurii","doi":"10.1109/IEPS.2018.8559585","DOIUrl":null,"url":null,"abstract":"Alternating current electric arc furnaces negatively influence the electrical grid that often causes power quality decrease. The traditionally applied measures and methods aim to at reduce or eliminate the consequences of such influence. This study proposed a schematic solution that targets the source of the influence and reduces the extent of negative factor generation. The proposed solution decreases the negative electromagnetic effect on a power supply grid and improves the furnace performance, through: increasing the furnace efficiency, reducing the voltage fluctuations in the electrical grid by 4 times, equalizing phase loads, simplifying the power control of the furnace decreasing the power losses in the electrical grid, reducing the dynamic efforts for electrical equipment.","PeriodicalId":340150,"journal":{"name":"2018 IEEE 3rd International Conference on Intelligent Energy and Power Systems (IEPS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"The Efficient Power Supply Scheme of Alternating Current Electric Arc Furnaces\",\"authors\":\"Malinovskyi Anton, Turkovskyi Volodymyr, Muzychak Andrii, Turkovskyi Yurii\",\"doi\":\"10.1109/IEPS.2018.8559585\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Alternating current electric arc furnaces negatively influence the electrical grid that often causes power quality decrease. The traditionally applied measures and methods aim to at reduce or eliminate the consequences of such influence. This study proposed a schematic solution that targets the source of the influence and reduces the extent of negative factor generation. The proposed solution decreases the negative electromagnetic effect on a power supply grid and improves the furnace performance, through: increasing the furnace efficiency, reducing the voltage fluctuations in the electrical grid by 4 times, equalizing phase loads, simplifying the power control of the furnace decreasing the power losses in the electrical grid, reducing the dynamic efforts for electrical equipment.\",\"PeriodicalId\":340150,\"journal\":{\"name\":\"2018 IEEE 3rd International Conference on Intelligent Energy and Power Systems (IEPS)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE 3rd International Conference on Intelligent Energy and Power Systems (IEPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEPS.2018.8559585\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE 3rd International Conference on Intelligent Energy and Power Systems (IEPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEPS.2018.8559585","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

交流电弧炉对电网产生负面影响,经常导致电能质量下降。传统上采用的措施和方法旨在减少或消除这种影响的后果。本研究提出了一种针对影响源,减少负面因素产生程度的方案。该方案通过提高炉体效率,将电网电压波动降低4倍,平衡相负荷,简化炉体功率控制,降低电网功率损耗,减少用电设备的动态负荷,降低了对电网的负电磁效应,改善了炉体性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Efficient Power Supply Scheme of Alternating Current Electric Arc Furnaces
Alternating current electric arc furnaces negatively influence the electrical grid that often causes power quality decrease. The traditionally applied measures and methods aim to at reduce or eliminate the consequences of such influence. This study proposed a schematic solution that targets the source of the influence and reduces the extent of negative factor generation. The proposed solution decreases the negative electromagnetic effect on a power supply grid and improves the furnace performance, through: increasing the furnace efficiency, reducing the voltage fluctuations in the electrical grid by 4 times, equalizing phase loads, simplifying the power control of the furnace decreasing the power losses in the electrical grid, reducing the dynamic efforts for electrical equipment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信