A. Fardoun, M. S. Al Naimi, Reema Al Zarooni, H. Noura
{"title":"一种五相交流电动机故障监测电路","authors":"A. Fardoun, M. S. Al Naimi, Reema Al Zarooni, H. Noura","doi":"10.1109/ACTEA.2009.5227847","DOIUrl":null,"url":null,"abstract":"This paper presents a fault monitoring approach for five-phase AC motor under motor short and open fault conditions. The proposed circuit monitor faults in the AC Drive, disconnects the drive from the fault in a designed way to keep the motor operating correctly at derated capability. The proposed approach allows using existing solution for open circuit conditions. The paper covers most mechanical & electrical failures in the drive. The effect of the winding space on the magnitude and phase of magnetic field under the above conditions are analyzed and presented.","PeriodicalId":308909,"journal":{"name":"2009 International Conference on Advances in Computational Tools for Engineering Applications","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A fault monitoring circuit for five phase AC motor\",\"authors\":\"A. Fardoun, M. S. Al Naimi, Reema Al Zarooni, H. Noura\",\"doi\":\"10.1109/ACTEA.2009.5227847\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a fault monitoring approach for five-phase AC motor under motor short and open fault conditions. The proposed circuit monitor faults in the AC Drive, disconnects the drive from the fault in a designed way to keep the motor operating correctly at derated capability. The proposed approach allows using existing solution for open circuit conditions. The paper covers most mechanical & electrical failures in the drive. The effect of the winding space on the magnitude and phase of magnetic field under the above conditions are analyzed and presented.\",\"PeriodicalId\":308909,\"journal\":{\"name\":\"2009 International Conference on Advances in Computational Tools for Engineering Applications\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Conference on Advances in Computational Tools for Engineering Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ACTEA.2009.5227847\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference on Advances in Computational Tools for Engineering Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ACTEA.2009.5227847","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A fault monitoring circuit for five phase AC motor
This paper presents a fault monitoring approach for five-phase AC motor under motor short and open fault conditions. The proposed circuit monitor faults in the AC Drive, disconnects the drive from the fault in a designed way to keep the motor operating correctly at derated capability. The proposed approach allows using existing solution for open circuit conditions. The paper covers most mechanical & electrical failures in the drive. The effect of the winding space on the magnitude and phase of magnetic field under the above conditions are analyzed and presented.