A. Voloshin, E. Voloshin, A. Kovalenko, S. A. Danilov, V. S. Sazanov
{"title":"继电保护设定点自动计算系统","authors":"A. Voloshin, E. Voloshin, A. Kovalenko, S. A. Danilov, V. S. Sazanov","doi":"10.1109/RPA51116.2020.9301730","DOIUrl":null,"url":null,"abstract":"Currently, Russia is increasingly using low-power power plants that are connected to medium-voltage distribution networks in close proximity to electricity consumers, making the distribution network active. In active distribution networks, there are a number of problems associated with changing a operating modes of the network: – a direction of power flows along power lines becomes possible in both directions; – the ratio of operating currents to short-circuit currents depends significantly on the operating mode of generating units included in the distribution network; – multi-way recharge of the short-circuit point becomes possible; – there are previously non-typical modes for distribution networks, such as swinging, asynchronous running.","PeriodicalId":299510,"journal":{"name":"2020 3rd International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)","volume":"03 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"System for Automatic Calculation of Relay Protection Set Points\",\"authors\":\"A. Voloshin, E. Voloshin, A. Kovalenko, S. A. Danilov, V. S. Sazanov\",\"doi\":\"10.1109/RPA51116.2020.9301730\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Currently, Russia is increasingly using low-power power plants that are connected to medium-voltage distribution networks in close proximity to electricity consumers, making the distribution network active. In active distribution networks, there are a number of problems associated with changing a operating modes of the network: – a direction of power flows along power lines becomes possible in both directions; – the ratio of operating currents to short-circuit currents depends significantly on the operating mode of generating units included in the distribution network; – multi-way recharge of the short-circuit point becomes possible; – there are previously non-typical modes for distribution networks, such as swinging, asynchronous running.\",\"PeriodicalId\":299510,\"journal\":{\"name\":\"2020 3rd International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)\",\"volume\":\"03 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 3rd International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RPA51116.2020.9301730\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RPA51116.2020.9301730","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
System for Automatic Calculation of Relay Protection Set Points
Currently, Russia is increasingly using low-power power plants that are connected to medium-voltage distribution networks in close proximity to electricity consumers, making the distribution network active. In active distribution networks, there are a number of problems associated with changing a operating modes of the network: – a direction of power flows along power lines becomes possible in both directions; – the ratio of operating currents to short-circuit currents depends significantly on the operating mode of generating units included in the distribution network; – multi-way recharge of the short-circuit point becomes possible; – there are previously non-typical modes for distribution networks, such as swinging, asynchronous running.