一种可靠和准确的方法来评估最先进的pmosfet快速wlr的NBTI行为

C. Schlunder, R. Vollertsen, W. Gustin, H. Reisinger
{"title":"一种可靠和准确的方法来评估最先进的pmosfet快速wlr的NBTI行为","authors":"C. Schlunder, R. Vollertsen, W. Gustin, H. Reisinger","doi":"10.1109/ESSDERC.2007.4430896","DOIUrl":null,"url":null,"abstract":"NBTI is a key challenge of today's technologies and could be assessed so far only by relative long stress durations. The On-the-fly characterization seems to be a proper method for fast-WLR, but shows also some problems. This work describes for the first time the application of OTF in combination with self-heating test structures and a method to correct the initial value without special equipment. Challenges and different solutions are introduced and discussed. We compare data from very fast non standard measurements with fWLR data acquired with regular test equipment. The insight we gained suggests that fWLR provides a suitable means for fast NBTI monitoring.","PeriodicalId":103959,"journal":{"name":"ESSDERC 2007 - 37th European Solid State Device Research Conference","volume":"111 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"A reliable and accurate approach to assess NBTI behavior of state-of-the-art pMOSFETs with fast-WLR\",\"authors\":\"C. Schlunder, R. Vollertsen, W. Gustin, H. Reisinger\",\"doi\":\"10.1109/ESSDERC.2007.4430896\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"NBTI is a key challenge of today's technologies and could be assessed so far only by relative long stress durations. The On-the-fly characterization seems to be a proper method for fast-WLR, but shows also some problems. This work describes for the first time the application of OTF in combination with self-heating test structures and a method to correct the initial value without special equipment. Challenges and different solutions are introduced and discussed. We compare data from very fast non standard measurements with fWLR data acquired with regular test equipment. The insight we gained suggests that fWLR provides a suitable means for fast NBTI monitoring.\",\"PeriodicalId\":103959,\"journal\":{\"name\":\"ESSDERC 2007 - 37th European Solid State Device Research Conference\",\"volume\":\"111 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ESSDERC 2007 - 37th European Solid State Device Research Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESSDERC.2007.4430896\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ESSDERC 2007 - 37th European Solid State Device Research Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESSDERC.2007.4430896","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

NBTI是当今技术的一个关键挑战,迄今为止只能通过相对较长的应力持续时间来评估。动态表征似乎是一种合适的快速wlr方法,但也存在一些问题。本文首次介绍了OTF与自热测试结构相结合的应用,以及一种无需特殊设备即可校正初始值的方法。介绍和讨论了挑战和不同的解决方案。我们将非常快速的非标准测量数据与常规测试设备获得的fWLR数据进行比较。我们获得的见解表明,fWLR为快速监测NBTI提供了一种合适的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A reliable and accurate approach to assess NBTI behavior of state-of-the-art pMOSFETs with fast-WLR
NBTI is a key challenge of today's technologies and could be assessed so far only by relative long stress durations. The On-the-fly characterization seems to be a proper method for fast-WLR, but shows also some problems. This work describes for the first time the application of OTF in combination with self-heating test structures and a method to correct the initial value without special equipment. Challenges and different solutions are introduced and discussed. We compare data from very fast non standard measurements with fWLR data acquired with regular test equipment. The insight we gained suggests that fWLR provides a suitable means for fast NBTI monitoring.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信