通用直流母线充电系统的电动汽车与太阳能,风能,电池和燃料电池的来源

Pavitra Shukl, Bhim Singh
{"title":"通用直流母线充电系统的电动汽车与太阳能,风能,电池和燃料电池的来源","authors":"Pavitra Shukl, Bhim Singh","doi":"10.1109/GlobConPT57482.2022.9938196","DOIUrl":null,"url":null,"abstract":"A promising solution to meet the growing charging demand of electric vehicles (EVs), is to incorporate renewable energy resources based charging stations. Thus, a cascaded IIR filter is utilized here for the EV charging system based on PV array, fuel cell stack and wind turbine sources. The satisfactory operation during the grid availability/unavailability is attained through the current and voltage based control mechanisms, along with the seamless transition capability via switching (STS-1/0) of the static transfer switches. Therefore, for adequate operation during modes associated with grid existence and non-existence, a cascaded IIR filter is utilized. Moreover, with respect to various weak grid conditions, adequate system performance is observed.","PeriodicalId":431406,"journal":{"name":"2022 IEEE Global Conference on Computing, Power and Communication Technologies (GlobConPT)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Common DC Bus Charging System for EVs with Solar, Wind, Battery and Fuel Cell Sources\",\"authors\":\"Pavitra Shukl, Bhim Singh\",\"doi\":\"10.1109/GlobConPT57482.2022.9938196\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A promising solution to meet the growing charging demand of electric vehicles (EVs), is to incorporate renewable energy resources based charging stations. Thus, a cascaded IIR filter is utilized here for the EV charging system based on PV array, fuel cell stack and wind turbine sources. The satisfactory operation during the grid availability/unavailability is attained through the current and voltage based control mechanisms, along with the seamless transition capability via switching (STS-1/0) of the static transfer switches. Therefore, for adequate operation during modes associated with grid existence and non-existence, a cascaded IIR filter is utilized. Moreover, with respect to various weak grid conditions, adequate system performance is observed.\",\"PeriodicalId\":431406,\"journal\":{\"name\":\"2022 IEEE Global Conference on Computing, Power and Communication Technologies (GlobConPT)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE Global Conference on Computing, Power and Communication Technologies (GlobConPT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GlobConPT57482.2022.9938196\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Global Conference on Computing, Power and Communication Technologies (GlobConPT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GlobConPT57482.2022.9938196","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了满足电动汽车日益增长的充电需求,一个很有希望的解决方案是建立基于可再生能源的充电站。因此,本文将级联IIR滤波器用于基于光伏阵列、燃料电池堆和风力涡轮机源的电动汽车充电系统。通过基于电流和电压的控制机制,以及通过静态转换开关(STS-1/0)的无缝转换能力,在电网可用/不可用期间实现令人满意的运行。因此,为了在与网格存在和不存在相关的模式期间进行适当的操作,使用了级联IIR滤波器。此外,在各种弱电网条件下,系统性能良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Common DC Bus Charging System for EVs with Solar, Wind, Battery and Fuel Cell Sources
A promising solution to meet the growing charging demand of electric vehicles (EVs), is to incorporate renewable energy resources based charging stations. Thus, a cascaded IIR filter is utilized here for the EV charging system based on PV array, fuel cell stack and wind turbine sources. The satisfactory operation during the grid availability/unavailability is attained through the current and voltage based control mechanisms, along with the seamless transition capability via switching (STS-1/0) of the static transfer switches. Therefore, for adequate operation during modes associated with grid existence and non-existence, a cascaded IIR filter is utilized. Moreover, with respect to various weak grid conditions, adequate system performance is observed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信