使用智能电表对低压馈线进行连续线路阻抗评估

Jacques Wattel, M. Tomlinson, J. Beukes, T. Mouton
{"title":"使用智能电表对低压馈线进行连续线路阻抗评估","authors":"Jacques Wattel, M. Tomlinson, J. Beukes, T. Mouton","doi":"10.1109/ISGTEurope.2018.8571667","DOIUrl":null,"url":null,"abstract":"This paper investigates the use of smart meters to measure the line impedance of LV feeders to provide information on the adequacy of protection settings, deteriorating infrastructure, damaged infrastructure, etc. The consequences of a broken neutral conductor are examined for the two earthing schemes used in South Africa. The feasibility of measuring the line impedance using smart meters is evaluated using an experimental model of an LV feeder with experimental smart meters located at customer installations. Experimental results showed that the smart meters can be used to estimate the line impedance to detect a possible broken neutral or protective earth and neutral conductor failure.","PeriodicalId":302863,"journal":{"name":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continuous Line Impedance Assessment of LV Feeders Using Smart Meters\",\"authors\":\"Jacques Wattel, M. Tomlinson, J. Beukes, T. Mouton\",\"doi\":\"10.1109/ISGTEurope.2018.8571667\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper investigates the use of smart meters to measure the line impedance of LV feeders to provide information on the adequacy of protection settings, deteriorating infrastructure, damaged infrastructure, etc. The consequences of a broken neutral conductor are examined for the two earthing schemes used in South Africa. The feasibility of measuring the line impedance using smart meters is evaluated using an experimental model of an LV feeder with experimental smart meters located at customer installations. Experimental results showed that the smart meters can be used to estimate the line impedance to detect a possible broken neutral or protective earth and neutral conductor failure.\",\"PeriodicalId\":302863,\"journal\":{\"name\":\"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"volume\":\"71 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEurope.2018.8571667\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2018.8571667","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究了如何使用智能电表测量低压馈线的线路阻抗,以提供有关保护设置的适当性、基础设施恶化、基础设施损坏等方面的信息。本文针对南非使用的两种接地方案,研究了中性线断裂的后果。使用智能电表测量线路阻抗的可行性是通过一个低压馈线实验模型和位于用户安装处的实验性智能电表进行评估的。实验结果表明,智能电表可用于估算线路阻抗,以检测可能出现的中性线断裂或保护接地和中性线导体故障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Continuous Line Impedance Assessment of LV Feeders Using Smart Meters
This paper investigates the use of smart meters to measure the line impedance of LV feeders to provide information on the adequacy of protection settings, deteriorating infrastructure, damaged infrastructure, etc. The consequences of a broken neutral conductor are examined for the two earthing schemes used in South Africa. The feasibility of measuring the line impedance using smart meters is evaluated using an experimental model of an LV feeder with experimental smart meters located at customer installations. Experimental results showed that the smart meters can be used to estimate the line impedance to detect a possible broken neutral or protective earth and neutral conductor failure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信