低成本BLE手环作为患者监测平台:范围限制

Kristina Zovko, D. Begusic, P. Šolić, T. Perković
{"title":"低成本BLE手环作为患者监测平台:范围限制","authors":"Kristina Zovko, D. Begusic, P. Šolić, T. Perković","doi":"10.1109/HealthCom54947.2022.9982765","DOIUrl":null,"url":null,"abstract":"This paper presents results of the signal strength of the BLE v4.0 protocol used by the low-cost bracelet in an indoor environment. Low-cost BLE bracelets can be utilized as a patient monitoring platform, because has the ability to measure the vital parameters of patients. Thus providing the possibility of usage in hospitals and nursing homes for constant monitoring of patients. The application such a bracelets in a real environment has several limitations, and one of them is the signal range of the bracelet tested in this paper. The obtained results are presented together with the simulations for the frequency of 2.4GHz.With a range of up to 18.03m for the low-cost BLE bracelet in an indoor environment with obstacles.","PeriodicalId":202664,"journal":{"name":"2022 IEEE International Conference on E-health Networking, Application & Services (HealthCom)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Low-cost BLE bracelet as patients monitoring platform: range restrictions\",\"authors\":\"Kristina Zovko, D. Begusic, P. Šolić, T. Perković\",\"doi\":\"10.1109/HealthCom54947.2022.9982765\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents results of the signal strength of the BLE v4.0 protocol used by the low-cost bracelet in an indoor environment. Low-cost BLE bracelets can be utilized as a patient monitoring platform, because has the ability to measure the vital parameters of patients. Thus providing the possibility of usage in hospitals and nursing homes for constant monitoring of patients. The application such a bracelets in a real environment has several limitations, and one of them is the signal range of the bracelet tested in this paper. The obtained results are presented together with the simulations for the frequency of 2.4GHz.With a range of up to 18.03m for the low-cost BLE bracelet in an indoor environment with obstacles.\",\"PeriodicalId\":202664,\"journal\":{\"name\":\"2022 IEEE International Conference on E-health Networking, Application & Services (HealthCom)\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE International Conference on E-health Networking, Application & Services (HealthCom)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HealthCom54947.2022.9982765\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference on E-health Networking, Application & Services (HealthCom)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HealthCom54947.2022.9982765","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了低成本手环在室内环境下使用BLE v4.0协议的信号强度结果。低成本的BLE手环可以作为患者监护平台,因为它具有测量患者重要参数的能力。因此,提供了在医院和疗养院使用的可能性,以持续监测病人。这种手环在实际环境中的应用有几个限制,其中之一就是本文测试的手环的信号范围。给出了仿真结果,并对2.4GHz频率下的仿真结果进行了分析。低成本BLE手环在有障碍物的室内环境下的探测范围可达18.03米。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Low-cost BLE bracelet as patients monitoring platform: range restrictions
This paper presents results of the signal strength of the BLE v4.0 protocol used by the low-cost bracelet in an indoor environment. Low-cost BLE bracelets can be utilized as a patient monitoring platform, because has the ability to measure the vital parameters of patients. Thus providing the possibility of usage in hospitals and nursing homes for constant monitoring of patients. The application such a bracelets in a real environment has several limitations, and one of them is the signal range of the bracelet tested in this paper. The obtained results are presented together with the simulations for the frequency of 2.4GHz.With a range of up to 18.03m for the low-cost BLE bracelet in an indoor environment with obstacles.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信