Y. Wang, Xingxing Huang, Bo Hu, Tianming Kang, Zhen Liu, Chengming Liu, Lingjiu Zhou, Zhengwei Wang
{"title":"径向安装偏差对高质量1000mw混流式水轮机流动特性的影响","authors":"Y. Wang, Xingxing Huang, Bo Hu, Tianming Kang, Zhen Liu, Chengming Liu, Lingjiu Zhou, Zhengwei Wang","doi":"10.1109/ICESGE56040.2022.10180369","DOIUrl":null,"url":null,"abstract":"In order to preliminarily explore the influence of radial installation deviation on the internal flow of large turbine, we take a high-quality 1000 MW Francis turbine unit as the research object to explore what kind of situation will occur when there is a radial installation deviation of 0.5 mm away from the spiral case direction of the steady flow. We found that, firstly, the pressure in the place with small clearance is higher than that in other places. Secondly, in the parts of the flow, different parts are affected to different degrees. Whether it is pressure or speed, the crown chamber is affected most seriously, while the bottom ring chamber has almost no influence.","PeriodicalId":120565,"journal":{"name":"2022 International Conference on Environmental Science and Green Energy (ICESGE)","volume":"822 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of Radial Installation Deviation on the Flow Characteristics of a High-Quality 1000 MW Francis Turbine\",\"authors\":\"Y. Wang, Xingxing Huang, Bo Hu, Tianming Kang, Zhen Liu, Chengming Liu, Lingjiu Zhou, Zhengwei Wang\",\"doi\":\"10.1109/ICESGE56040.2022.10180369\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to preliminarily explore the influence of radial installation deviation on the internal flow of large turbine, we take a high-quality 1000 MW Francis turbine unit as the research object to explore what kind of situation will occur when there is a radial installation deviation of 0.5 mm away from the spiral case direction of the steady flow. We found that, firstly, the pressure in the place with small clearance is higher than that in other places. Secondly, in the parts of the flow, different parts are affected to different degrees. Whether it is pressure or speed, the crown chamber is affected most seriously, while the bottom ring chamber has almost no influence.\",\"PeriodicalId\":120565,\"journal\":{\"name\":\"2022 International Conference on Environmental Science and Green Energy (ICESGE)\",\"volume\":\"822 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 International Conference on Environmental Science and Green Energy (ICESGE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICESGE56040.2022.10180369\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Environmental Science and Green Energy (ICESGE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICESGE56040.2022.10180369","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Influence of Radial Installation Deviation on the Flow Characteristics of a High-Quality 1000 MW Francis Turbine
In order to preliminarily explore the influence of radial installation deviation on the internal flow of large turbine, we take a high-quality 1000 MW Francis turbine unit as the research object to explore what kind of situation will occur when there is a radial installation deviation of 0.5 mm away from the spiral case direction of the steady flow. We found that, firstly, the pressure in the place with small clearance is higher than that in other places. Secondly, in the parts of the flow, different parts are affected to different degrees. Whether it is pressure or speed, the crown chamber is affected most seriously, while the bottom ring chamber has almost no influence.