{"title":"热风空调管道作为60 GHz通信信道性能的实验验证","authors":"Esha Bangar, K. Kiasaleh","doi":"10.1109/LANMAN49260.2020.9153253","DOIUrl":null,"url":null,"abstract":"We demonstrate heating, ventilation, and air conditioning (HVAC) ducts as viable and inexpensive high-speed communication links inside of buildings at millimeter (mm-wave) frequencies. HVAC ducts are hollow metal pipes which can be used as waveguides for mm-wave signals. Indoor communication at mm-wave using HVAC ducts outperforms the existing communication methods and the same has been validated through theoretical and extensive experimental results here. Measurement and system calculations show that a received signal strength indicator (RSSI) of -$50\\mathrm {d}\\mathrm {B}\\mathrm {m}$ and data rates in excess of 600 Mbps can be achieved over a distance of up to 8 m using HVAC ducts at 60 GHz.","PeriodicalId":431494,"journal":{"name":"2020 IEEE International Symposium on Local and Metropolitan Area Networks (LANMAN","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Experimental Validation of the Performance of Heating, Ventilation and Air Conditioning Ducts as Communication Channel at 60 GHz\",\"authors\":\"Esha Bangar, K. Kiasaleh\",\"doi\":\"10.1109/LANMAN49260.2020.9153253\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We demonstrate heating, ventilation, and air conditioning (HVAC) ducts as viable and inexpensive high-speed communication links inside of buildings at millimeter (mm-wave) frequencies. HVAC ducts are hollow metal pipes which can be used as waveguides for mm-wave signals. Indoor communication at mm-wave using HVAC ducts outperforms the existing communication methods and the same has been validated through theoretical and extensive experimental results here. Measurement and system calculations show that a received signal strength indicator (RSSI) of -$50\\\\mathrm {d}\\\\mathrm {B}\\\\mathrm {m}$ and data rates in excess of 600 Mbps can be achieved over a distance of up to 8 m using HVAC ducts at 60 GHz.\",\"PeriodicalId\":431494,\"journal\":{\"name\":\"2020 IEEE International Symposium on Local and Metropolitan Area Networks (LANMAN\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE International Symposium on Local and Metropolitan Area Networks (LANMAN\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/LANMAN49260.2020.9153253\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Symposium on Local and Metropolitan Area Networks (LANMAN","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/LANMAN49260.2020.9153253","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experimental Validation of the Performance of Heating, Ventilation and Air Conditioning Ducts as Communication Channel at 60 GHz
We demonstrate heating, ventilation, and air conditioning (HVAC) ducts as viable and inexpensive high-speed communication links inside of buildings at millimeter (mm-wave) frequencies. HVAC ducts are hollow metal pipes which can be used as waveguides for mm-wave signals. Indoor communication at mm-wave using HVAC ducts outperforms the existing communication methods and the same has been validated through theoretical and extensive experimental results here. Measurement and system calculations show that a received signal strength indicator (RSSI) of -$50\mathrm {d}\mathrm {B}\mathrm {m}$ and data rates in excess of 600 Mbps can be achieved over a distance of up to 8 m using HVAC ducts at 60 GHz.