基于相量的线路参数估计分析方法通过PMU实际数据验证

E. Satsuk, A. Zhukov, D. Dubinin, I. Ivanov, A. Murzin
{"title":"基于相量的线路参数估计分析方法通过PMU实际数据验证","authors":"E. Satsuk, A. Zhukov, D. Dubinin, I. Ivanov, A. Murzin","doi":"10.1109/SGSMA51733.2022.9806007","DOIUrl":null,"url":null,"abstract":"Synchrophasor measurements enable the validation of transmission line parameters utilized by state estimation software, relays and fault locators. Despite quite a few algorithms proposed earlier, practical implementation results are almost absent, and only simulated phasors are often taken for testing. This work provides a simple regression-based approach for positive sequence line parameter estimation through line terminal PMU data. The key feature is thorough testing of the proposed technique on real phasor archives collected from four different lines located in two distinct power systems. Promising results obtained in such a \"black-box\" rather than software-only impractical simulations serve as an indicator of the algorithm’s validity. We also highlight an attempt of zero sequence line parameter estimation based on PMU archives collected under power system imbalance. The derived results can be thought of as a first step towards putting PMU-driven parameter estimation methods into practice.","PeriodicalId":256954,"journal":{"name":"2022 International Conference on Smart Grid Synchronized Measurements and Analytics (SGSMA)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analytical Approach to Phasor-based Line Parameter Estimation Verified Through Real PMU Data\",\"authors\":\"E. Satsuk, A. Zhukov, D. Dubinin, I. Ivanov, A. Murzin\",\"doi\":\"10.1109/SGSMA51733.2022.9806007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Synchrophasor measurements enable the validation of transmission line parameters utilized by state estimation software, relays and fault locators. Despite quite a few algorithms proposed earlier, practical implementation results are almost absent, and only simulated phasors are often taken for testing. This work provides a simple regression-based approach for positive sequence line parameter estimation through line terminal PMU data. The key feature is thorough testing of the proposed technique on real phasor archives collected from four different lines located in two distinct power systems. Promising results obtained in such a \\\"black-box\\\" rather than software-only impractical simulations serve as an indicator of the algorithm’s validity. We also highlight an attempt of zero sequence line parameter estimation based on PMU archives collected under power system imbalance. The derived results can be thought of as a first step towards putting PMU-driven parameter estimation methods into practice.\",\"PeriodicalId\":256954,\"journal\":{\"name\":\"2022 International Conference on Smart Grid Synchronized Measurements and Analytics (SGSMA)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 International Conference on Smart Grid Synchronized Measurements and Analytics (SGSMA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SGSMA51733.2022.9806007\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Smart Grid Synchronized Measurements and Analytics (SGSMA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SGSMA51733.2022.9806007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

同步相量测量能够验证状态估计软件、继电器和故障定位器所使用的传输线参数。尽管之前提出了相当多的算法,但实际的实现结果几乎没有,而且通常只采用模拟相量进行测试。这项工作提供了一种简单的基于回归的方法,通过线端PMU数据估计正序列线参数。关键特征是对所提出的技术在两个不同电力系统中的四条不同线路上收集的真实相量档案进行了彻底的测试。在这样一个“黑盒”中获得的有希望的结果,而不是仅仅在软件上不切实际的模拟,作为算法有效性的一个指标。本文还重点介绍了在电力系统不平衡情况下基于PMU档案的零序线参数估计的尝试。导出的结果可以被认为是将pmu驱动的参数估计方法付诸实践的第一步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analytical Approach to Phasor-based Line Parameter Estimation Verified Through Real PMU Data
Synchrophasor measurements enable the validation of transmission line parameters utilized by state estimation software, relays and fault locators. Despite quite a few algorithms proposed earlier, practical implementation results are almost absent, and only simulated phasors are often taken for testing. This work provides a simple regression-based approach for positive sequence line parameter estimation through line terminal PMU data. The key feature is thorough testing of the proposed technique on real phasor archives collected from four different lines located in two distinct power systems. Promising results obtained in such a "black-box" rather than software-only impractical simulations serve as an indicator of the algorithm’s validity. We also highlight an attempt of zero sequence line parameter estimation based on PMU archives collected under power system imbalance. The derived results can be thought of as a first step towards putting PMU-driven parameter estimation methods into practice.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信