W. Fischer, H. Hahn, W. Mackay, T. Satogata, N. Tsoupas, W. Zhang
{"title":"束流注入RHIC","authors":"W. Fischer, H. Hahn, W. Mackay, T. Satogata, N. Tsoupas, W. Zhang","doi":"10.1109/PAC.1997.749595","DOIUrl":null,"url":null,"abstract":"During the RHIC sextant test in January 1997 beam was injected into a sixth of one of the rings for the first time. We describe the injection zone and its bottlenecks. We report on the commissioning of the injection system, on beam based measurements of the kickers and the application program to steer the beam.","PeriodicalId":122662,"journal":{"name":"Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Beam injection into RHIC\",\"authors\":\"W. Fischer, H. Hahn, W. Mackay, T. Satogata, N. Tsoupas, W. Zhang\",\"doi\":\"10.1109/PAC.1997.749595\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"During the RHIC sextant test in January 1997 beam was injected into a sixth of one of the rings for the first time. We describe the injection zone and its bottlenecks. We report on the commissioning of the injection system, on beam based measurements of the kickers and the application program to steer the beam.\",\"PeriodicalId\":122662,\"journal\":{\"name\":\"Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PAC.1997.749595\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAC.1997.749595","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
During the RHIC sextant test in January 1997 beam was injected into a sixth of one of the rings for the first time. We describe the injection zone and its bottlenecks. We report on the commissioning of the injection system, on beam based measurements of the kickers and the application program to steer the beam.