网络攻击对带电压支撑装置的智能电网暂态稳定的影响

Bo Chen, S. Mashayekh, K. Butler-Purry, D. Kundur
{"title":"网络攻击对带电压支撑装置的智能电网暂态稳定的影响","authors":"Bo Chen, S. Mashayekh, K. Butler-Purry, D. Kundur","doi":"10.1109/PESMG.2013.6672740","DOIUrl":null,"url":null,"abstract":"Cyber security is becoming a major concern of smart grids, as the functionality of a smart grid is highly dependent on the cyber communication. Therefore, it is important to study the impact of cyber attacks on smart grids. This paper discusses several types of cyber attacks. Then, it presents results of studies of impacts on transient angle and transient voltage stability due to cyber attacks on two voltage support devices, SVC and STATCOM, in an 8-bus test system. The 8 bus system and voltage devices are simulated and the stability analysis is performed with DSATools™. The results showed that some modification cyber attacks can make the system angle or voltage unstable, following a physical fault in the system.","PeriodicalId":433870,"journal":{"name":"2013 IEEE Power & Energy Society General Meeting","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"64","resultStr":"{\"title\":\"Impact of cyber attacks on transient stability of smart grids with voltage support devices\",\"authors\":\"Bo Chen, S. Mashayekh, K. Butler-Purry, D. Kundur\",\"doi\":\"10.1109/PESMG.2013.6672740\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cyber security is becoming a major concern of smart grids, as the functionality of a smart grid is highly dependent on the cyber communication. Therefore, it is important to study the impact of cyber attacks on smart grids. This paper discusses several types of cyber attacks. Then, it presents results of studies of impacts on transient angle and transient voltage stability due to cyber attacks on two voltage support devices, SVC and STATCOM, in an 8-bus test system. The 8 bus system and voltage devices are simulated and the stability analysis is performed with DSATools™. The results showed that some modification cyber attacks can make the system angle or voltage unstable, following a physical fault in the system.\",\"PeriodicalId\":433870,\"journal\":{\"name\":\"2013 IEEE Power & Energy Society General Meeting\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-07-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"64\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Power & Energy Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESMG.2013.6672740\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Power & Energy Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESMG.2013.6672740","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 64

摘要

由于智能电网的功能高度依赖于网络通信,网络安全正成为智能电网关注的焦点。因此,研究网络攻击对智能电网的影响具有重要意义。本文讨论了几种类型的网络攻击。然后,在8总线测试系统中,研究了网络攻击对SVC和STATCOM两种电压支持设备的暂态角和暂态电压稳定性的影响。对8总线系统和电压器件进行了仿真,并使用DSATools™进行了稳定性分析。结果表明,在系统发生物理故障后,一些修改后的网络攻击会使系统角度或电压不稳定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of cyber attacks on transient stability of smart grids with voltage support devices
Cyber security is becoming a major concern of smart grids, as the functionality of a smart grid is highly dependent on the cyber communication. Therefore, it is important to study the impact of cyber attacks on smart grids. This paper discusses several types of cyber attacks. Then, it presents results of studies of impacts on transient angle and transient voltage stability due to cyber attacks on two voltage support devices, SVC and STATCOM, in an 8-bus test system. The 8 bus system and voltage devices are simulated and the stability analysis is performed with DSATools™. The results showed that some modification cyber attacks can make the system angle or voltage unstable, following a physical fault in the system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信