{"title":"用分光光度法测定氧饱和度","authors":"E. Okada, Y. Shinozaki, H. Minamitani","doi":"10.1109/IECON.1993.339300","DOIUrl":null,"url":null,"abstract":"In this study a new technique to measure oxygen saturation in a single microvessel utilizing spectrophotometric determination is proposed. In principle the oxygen saturation can be measured by the optical methods which are based on Beer-Lambert law. However, light attenuation by cell scattering causes error of the measurement. To eliminate the influence of cell scattering, complete diffuse light was used in the proposed technique. The effect of using complete diffuse light was ascertained by the in-vitro experiments. The change of the oxygen saturation in the microvessel of rat mesentery was measured with the proposed technique. The experiments showed that the technique was possible to measure the oxygen saturation in the single microvessel.<<ETX>>","PeriodicalId":132101,"journal":{"name":"Proceedings of IECON '93 - 19th Annual Conference of IEEE Industrial Electronics","volume":"18 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Measurement of oxygen saturation utilizing spectrophotometric determination\",\"authors\":\"E. Okada, Y. Shinozaki, H. Minamitani\",\"doi\":\"10.1109/IECON.1993.339300\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study a new technique to measure oxygen saturation in a single microvessel utilizing spectrophotometric determination is proposed. In principle the oxygen saturation can be measured by the optical methods which are based on Beer-Lambert law. However, light attenuation by cell scattering causes error of the measurement. To eliminate the influence of cell scattering, complete diffuse light was used in the proposed technique. The effect of using complete diffuse light was ascertained by the in-vitro experiments. The change of the oxygen saturation in the microvessel of rat mesentery was measured with the proposed technique. The experiments showed that the technique was possible to measure the oxygen saturation in the single microvessel.<<ETX>>\",\"PeriodicalId\":132101,\"journal\":{\"name\":\"Proceedings of IECON '93 - 19th Annual Conference of IEEE Industrial Electronics\",\"volume\":\"18 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of IECON '93 - 19th Annual Conference of IEEE Industrial Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.1993.339300\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IECON '93 - 19th Annual Conference of IEEE Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.1993.339300","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Measurement of oxygen saturation utilizing spectrophotometric determination
In this study a new technique to measure oxygen saturation in a single microvessel utilizing spectrophotometric determination is proposed. In principle the oxygen saturation can be measured by the optical methods which are based on Beer-Lambert law. However, light attenuation by cell scattering causes error of the measurement. To eliminate the influence of cell scattering, complete diffuse light was used in the proposed technique. The effect of using complete diffuse light was ascertained by the in-vitro experiments. The change of the oxygen saturation in the microvessel of rat mesentery was measured with the proposed technique. The experiments showed that the technique was possible to measure the oxygen saturation in the single microvessel.<>