单相非线性负载三相异步发电机不平衡电流的缓解

S. Gao, A. Kumar
{"title":"单相非线性负载三相异步发电机不平衡电流的缓解","authors":"S. Gao, A. Kumar","doi":"10.1109/ICSET.2012.6357406","DOIUrl":null,"url":null,"abstract":"When a three-phase asynchronous generator (AG) feeds a single-phase load, using any one of the known single-phase operation modes, the currents and voltages are grossly unbalanced. The unbalances become more prominent when the machine is feeding single-phase nonlinear loads. In this paper, analysis of a STATCOM based unbalance mitigation technique has been presented which successfully eliminates the unbalances, especially on the current waveforms. This is an encouraging result as the current unbalances are more severe compared to that of voltage unbalances as the former would otherwise lead to overheating of the machine windings which will eventually cause puncture of the insulation and accelerate ageing of the machine. The STATCOM is designed based on calculating the direct-axis and quadrature-axis components of reference currents which are converted to three-phase reference source currents with the help of Inverse Park Transformation and then compared with the actual machine currents to generate the required pulses to trigger the IGBTs of the Voltage Source Inverter (VSI). A single-phase rectifier based load is considered. The scheme is modeled using Matlab/Simulink PSB and the simulation results are presented.","PeriodicalId":256740,"journal":{"name":"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Mitigation of unbalanced currents in three-phase asynchronous generator supplying single-phase nonlinear load\",\"authors\":\"S. Gao, A. Kumar\",\"doi\":\"10.1109/ICSET.2012.6357406\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When a three-phase asynchronous generator (AG) feeds a single-phase load, using any one of the known single-phase operation modes, the currents and voltages are grossly unbalanced. The unbalances become more prominent when the machine is feeding single-phase nonlinear loads. In this paper, analysis of a STATCOM based unbalance mitigation technique has been presented which successfully eliminates the unbalances, especially on the current waveforms. This is an encouraging result as the current unbalances are more severe compared to that of voltage unbalances as the former would otherwise lead to overheating of the machine windings which will eventually cause puncture of the insulation and accelerate ageing of the machine. The STATCOM is designed based on calculating the direct-axis and quadrature-axis components of reference currents which are converted to three-phase reference source currents with the help of Inverse Park Transformation and then compared with the actual machine currents to generate the required pulses to trigger the IGBTs of the Voltage Source Inverter (VSI). A single-phase rectifier based load is considered. The scheme is modeled using Matlab/Simulink PSB and the simulation results are presented.\",\"PeriodicalId\":256740,\"journal\":{\"name\":\"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSET.2012.6357406\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSET.2012.6357406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

当三相异步发电机(AG)为单相负载供电时,使用任何一种已知的单相运行模式,电流和电压都是严重不平衡的。在给单相非线性负载时,不平衡现象更为突出。本文分析了一种基于STATCOM的不平衡缓解技术,该技术成功地消除了不平衡,特别是电流波形上的不平衡。这是一个令人鼓舞的结果,因为电流不平衡比电压不平衡更严重,因为前者会导致机器绕组过热,最终导致绝缘穿孔,加速机器老化。STATCOM的设计基于对参考电流的直轴分量和正交轴分量的计算,通过逆Park变换将参考电流转换为三相参考源电流,然后与实际机器电流进行比较,从而产生触发电压源逆变器(VSI) igbt所需的脉冲。考虑基于单相整流器的负载。利用Matlab/Simulink PSB对该方案进行了建模,并给出了仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Mitigation of unbalanced currents in three-phase asynchronous generator supplying single-phase nonlinear load
When a three-phase asynchronous generator (AG) feeds a single-phase load, using any one of the known single-phase operation modes, the currents and voltages are grossly unbalanced. The unbalances become more prominent when the machine is feeding single-phase nonlinear loads. In this paper, analysis of a STATCOM based unbalance mitigation technique has been presented which successfully eliminates the unbalances, especially on the current waveforms. This is an encouraging result as the current unbalances are more severe compared to that of voltage unbalances as the former would otherwise lead to overheating of the machine windings which will eventually cause puncture of the insulation and accelerate ageing of the machine. The STATCOM is designed based on calculating the direct-axis and quadrature-axis components of reference currents which are converted to three-phase reference source currents with the help of Inverse Park Transformation and then compared with the actual machine currents to generate the required pulses to trigger the IGBTs of the Voltage Source Inverter (VSI). A single-phase rectifier based load is considered. The scheme is modeled using Matlab/Simulink PSB and the simulation results are presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信