[早期皮层正中神经体感诱发电位的地形图:常规使用方法的结果]。

H Buchner, I Ludwig, R Veldkamp, K Willmes, A Ferbert
{"title":"[早期皮层正中神经体感诱发电位的地形图:常规使用方法的结果]。","authors":"H Buchner,&nbsp;I Ludwig,&nbsp;R Veldkamp,&nbsp;K Willmes,&nbsp;A Ferbert","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The results from a topographic analysis of the early median nerve SEPs allowed to design a method for recording and analysing the SEPs in the routine laboratory. The detailed analysis of the topography of 50 normal subjects revealed: 1. An inter- and intraindividual variability of the location of the maximal amplitudes, 2. A significantly longer latency of the cortical potentials after left side stimulation, 3. A significantly higher amplitude of N20 after left side stimulation and 4. A significantly higher amplitude of the later potentials P25 and N30 after right side stimulation. It was shown that a 4-channel recording from the neck at C7 with a Fz-reference as well as from stimulus contralateral F3, CP3 and P3 or F4, CP4 and P4 with an stimulus contralateral earlobe reference provides all necessary parameters in comparison to an 20-channel recording. The definition of normal values has to take into account these results. Absolute maximum values were taken instead of the standard deviation because all amplitude values were proven to be not distributed normally. In 7 out of 30 MCA-stroke patients pathological SEP amplitudes were obtained using the 4-channel montage, whereas the 1-channel recording from CP3 and CP4 with a Fz-reference revealed normal amplitudes.</p>","PeriodicalId":75812,"journal":{"name":"EEG-EMG Zeitschrift fur Elektroenzephalographie, Elektromyographie und verwandte Gebiete","volume":"23 4","pages":"203-9"},"PeriodicalIF":0.0000,"publicationDate":"1992-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Topography of early cortical median nerve somatosensory evoked potentials: results for routine use of the method].\",\"authors\":\"H Buchner,&nbsp;I Ludwig,&nbsp;R Veldkamp,&nbsp;K Willmes,&nbsp;A Ferbert\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The results from a topographic analysis of the early median nerve SEPs allowed to design a method for recording and analysing the SEPs in the routine laboratory. The detailed analysis of the topography of 50 normal subjects revealed: 1. An inter- and intraindividual variability of the location of the maximal amplitudes, 2. A significantly longer latency of the cortical potentials after left side stimulation, 3. A significantly higher amplitude of N20 after left side stimulation and 4. A significantly higher amplitude of the later potentials P25 and N30 after right side stimulation. It was shown that a 4-channel recording from the neck at C7 with a Fz-reference as well as from stimulus contralateral F3, CP3 and P3 or F4, CP4 and P4 with an stimulus contralateral earlobe reference provides all necessary parameters in comparison to an 20-channel recording. The definition of normal values has to take into account these results. Absolute maximum values were taken instead of the standard deviation because all amplitude values were proven to be not distributed normally. In 7 out of 30 MCA-stroke patients pathological SEP amplitudes were obtained using the 4-channel montage, whereas the 1-channel recording from CP3 and CP4 with a Fz-reference revealed normal amplitudes.</p>\",\"PeriodicalId\":75812,\"journal\":{\"name\":\"EEG-EMG Zeitschrift fur Elektroenzephalographie, Elektromyographie und verwandte Gebiete\",\"volume\":\"23 4\",\"pages\":\"203-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EEG-EMG Zeitschrift fur Elektroenzephalographie, Elektromyographie und verwandte Gebiete\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EEG-EMG Zeitschrift fur Elektroenzephalographie, Elektromyographie und verwandte Gebiete","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

早期正中神经sep的地形分析结果允许设计一种在常规实验室中记录和分析sep的方法。对50例正常受试者的地形进行详细分析:最大振幅位置的个体间和个体内部的可变性,2。左侧刺激后皮层电位潜伏期明显延长;左侧刺激后的N20振幅显著增高;右侧刺激后,后电位P25和N30的振幅显著升高。结果表明,与20通道记录相比,从颈部C7处以fz为参考以及从刺激对侧F3, CP3和P3或F4, CP4和P4以刺激对侧耳垂为参考进行的4通道记录提供了所有必要的参数。正常值的定义必须考虑到这些结果。取绝对最大值而不是标准差,因为所有振幅值都证明不是正态分布。在30例mca -卒中患者中,有7例采用4通道蒙太奇获得病理SEP振幅,而CP3和CP4的1通道记录与fz参考显示正常振幅。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Topography of early cortical median nerve somatosensory evoked potentials: results for routine use of the method].

The results from a topographic analysis of the early median nerve SEPs allowed to design a method for recording and analysing the SEPs in the routine laboratory. The detailed analysis of the topography of 50 normal subjects revealed: 1. An inter- and intraindividual variability of the location of the maximal amplitudes, 2. A significantly longer latency of the cortical potentials after left side stimulation, 3. A significantly higher amplitude of N20 after left side stimulation and 4. A significantly higher amplitude of the later potentials P25 and N30 after right side stimulation. It was shown that a 4-channel recording from the neck at C7 with a Fz-reference as well as from stimulus contralateral F3, CP3 and P3 or F4, CP4 and P4 with an stimulus contralateral earlobe reference provides all necessary parameters in comparison to an 20-channel recording. The definition of normal values has to take into account these results. Absolute maximum values were taken instead of the standard deviation because all amplitude values were proven to be not distributed normally. In 7 out of 30 MCA-stroke patients pathological SEP amplitudes were obtained using the 4-channel montage, whereas the 1-channel recording from CP3 and CP4 with a Fz-reference revealed normal amplitudes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信