A. Sendin, I. Berganza, A. Arzuaga, A. Pulkkinen, I. Kim
{"title":"在西班牙部署的100,000多个PRIME智能电表的性能结果","authors":"A. Sendin, I. Berganza, A. Arzuaga, A. Pulkkinen, I. Kim","doi":"10.1109/SmartGridComm.2012.6485974","DOIUrl":null,"url":null,"abstract":"PRIME (PoweRline Intelligent Metering Evolution) is a narrowband Power Line Communications (PLC) technology targeted for use in smart metering applications. It is standardized as part of international Recommendations ITU-T G.9955 and G.9956, and there are currently a number of deployments by utilities in different markets which use it for a cost-effective, technically proven solution. This paper is a continuation of two previous ones presented in the first and second SmartGridComm Conferences, in which PRIME background and status were discussed, including interoperability tests and first results in multi-vendor deployments. This final article describes the network architecture which has been thoroughly tested and is currently being used by Iberdrola for its Smart Grid deployment, PRIME network deployment selections, a proposed classification for secondary substations based on experience, and finally the tools which are being used for analysis and acceptance tests, along with performance results.","PeriodicalId":143915,"journal":{"name":"2012 IEEE Third International Conference on Smart Grid Communications (SmartGridComm)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"46","resultStr":"{\"title\":\"Performance results from 100,000+ PRIME smart meters deployment in Spain\",\"authors\":\"A. Sendin, I. Berganza, A. Arzuaga, A. Pulkkinen, I. Kim\",\"doi\":\"10.1109/SmartGridComm.2012.6485974\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PRIME (PoweRline Intelligent Metering Evolution) is a narrowband Power Line Communications (PLC) technology targeted for use in smart metering applications. It is standardized as part of international Recommendations ITU-T G.9955 and G.9956, and there are currently a number of deployments by utilities in different markets which use it for a cost-effective, technically proven solution. This paper is a continuation of two previous ones presented in the first and second SmartGridComm Conferences, in which PRIME background and status were discussed, including interoperability tests and first results in multi-vendor deployments. This final article describes the network architecture which has been thoroughly tested and is currently being used by Iberdrola for its Smart Grid deployment, PRIME network deployment selections, a proposed classification for secondary substations based on experience, and finally the tools which are being used for analysis and acceptance tests, along with performance results.\",\"PeriodicalId\":143915,\"journal\":{\"name\":\"2012 IEEE Third International Conference on Smart Grid Communications (SmartGridComm)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"46\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Third International Conference on Smart Grid Communications (SmartGridComm)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SmartGridComm.2012.6485974\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Third International Conference on Smart Grid Communications (SmartGridComm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SmartGridComm.2012.6485974","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Performance results from 100,000+ PRIME smart meters deployment in Spain
PRIME (PoweRline Intelligent Metering Evolution) is a narrowband Power Line Communications (PLC) technology targeted for use in smart metering applications. It is standardized as part of international Recommendations ITU-T G.9955 and G.9956, and there are currently a number of deployments by utilities in different markets which use it for a cost-effective, technically proven solution. This paper is a continuation of two previous ones presented in the first and second SmartGridComm Conferences, in which PRIME background and status were discussed, including interoperability tests and first results in multi-vendor deployments. This final article describes the network architecture which has been thoroughly tested and is currently being used by Iberdrola for its Smart Grid deployment, PRIME network deployment selections, a proposed classification for secondary substations based on experience, and finally the tools which are being used for analysis and acceptance tests, along with performance results.