一种新的用于输配电系统无功功率评估的信号处理技术

A. Abiyev
{"title":"一种新的用于输配电系统无功功率评估的信号处理技术","authors":"A. Abiyev","doi":"10.1109/SECON.2008.4494319","DOIUrl":null,"url":null,"abstract":"This paper presents a new modified Walsh function (WF) based method for the measurement of reactive power (RP) in sinusoidal as well as in noise conditions. Proposed method simplifies the multiplication procedure to evaluate the reactive components from instantaneous power signal using peculiar properties of the WF. One of the advantages of proposed measurement approach is that in contrast to the known existing methods which involve phase shift operation of the input signal, the proposed technique does not require the time delay of the current signal to the pi/2 with respect to the voltage signal. Another advantage is related to the computational saving properties of the proposed approach coming from use of the Walsh Transform (WT) based signal processing method. Proposed method eliminates an influence of the prevalent third order current harmonic to and reduces the effect of the highest order current harmonics on the RP measurement results. Validity and effectiveness of the suggested method for evaluation of the RP components of the electrical power have been tested by use of a simulation tools developed on the base of \"Matlab\".","PeriodicalId":188817,"journal":{"name":"IEEE SoutheastCon 2008","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A new signal processing technique for evaluation of the reactive power in the power transmission and distribution systems\",\"authors\":\"A. Abiyev\",\"doi\":\"10.1109/SECON.2008.4494319\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a new modified Walsh function (WF) based method for the measurement of reactive power (RP) in sinusoidal as well as in noise conditions. Proposed method simplifies the multiplication procedure to evaluate the reactive components from instantaneous power signal using peculiar properties of the WF. One of the advantages of proposed measurement approach is that in contrast to the known existing methods which involve phase shift operation of the input signal, the proposed technique does not require the time delay of the current signal to the pi/2 with respect to the voltage signal. Another advantage is related to the computational saving properties of the proposed approach coming from use of the Walsh Transform (WT) based signal processing method. Proposed method eliminates an influence of the prevalent third order current harmonic to and reduces the effect of the highest order current harmonics on the RP measurement results. Validity and effectiveness of the suggested method for evaluation of the RP components of the electrical power have been tested by use of a simulation tools developed on the base of \\\"Matlab\\\".\",\"PeriodicalId\":188817,\"journal\":{\"name\":\"IEEE SoutheastCon 2008\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE SoutheastCon 2008\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SECON.2008.4494319\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE SoutheastCon 2008","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SECON.2008.4494319","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文提出了一种基于改进沃尔什函数(WF)的正弦和噪声条件下无功功率测量方法。该方法利用WF的特性,简化了从瞬时功率信号中求无功分量的乘法运算。所提出的测量方法的优点之一是,与已知的现有方法相比,这些方法涉及输入信号的相移操作,所提出的技术不需要电流信号相对于电压信号的时间延迟到pi/2。该方法的另一个优点是使用基于沃尔什变换(WT)的信号处理方法,从而节省了计算量。该方法消除了普遍存在的三阶电流谐波对RP测量结果的影响,降低了最高阶电流谐波对RP测量结果的影响。利用基于Matlab开发的仿真工具,对所提出的电力RP分量评估方法的有效性进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A new signal processing technique for evaluation of the reactive power in the power transmission and distribution systems
This paper presents a new modified Walsh function (WF) based method for the measurement of reactive power (RP) in sinusoidal as well as in noise conditions. Proposed method simplifies the multiplication procedure to evaluate the reactive components from instantaneous power signal using peculiar properties of the WF. One of the advantages of proposed measurement approach is that in contrast to the known existing methods which involve phase shift operation of the input signal, the proposed technique does not require the time delay of the current signal to the pi/2 with respect to the voltage signal. Another advantage is related to the computational saving properties of the proposed approach coming from use of the Walsh Transform (WT) based signal processing method. Proposed method eliminates an influence of the prevalent third order current harmonic to and reduces the effect of the highest order current harmonics on the RP measurement results. Validity and effectiveness of the suggested method for evaluation of the RP components of the electrical power have been tested by use of a simulation tools developed on the base of "Matlab".
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信