液氮温度下高温超导三轴5m模型电缆局部放电测量

I. Sauers, D. James, E. Tuncer, A. Ellis, M. Pace
{"title":"液氮温度下高温超导三轴5m模型电缆局部放电测量","authors":"I. Sauers, D. James, E. Tuncer, A. Ellis, M. Pace","doi":"10.1109/CEIDP.2006.312019","DOIUrl":null,"url":null,"abstract":"A prototype 5-m triaxial high temperature superconducting (HTS) distribution class cable using a cold dielectric design was tested at high voltage under various conditions including AC, impulse and partial discharge (PD). The dielectric consists of wrapped synthetic tape insulation with liquid nitrogen filling the butt-gaps. In this paper we report on the partial discharge signals in the cable and methods for data analysis. All measurements were made cold in liquid nitrogen. The data will be presented in terms of PD amplitude and energy. Partial discharge signals were observed in the presence of large amounts of background noise due to the inverter circuits of the cryogenic system and these issues will also be discussed.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Partial discharge measurements in a high temperature superconducting triaxial 5-m model cable at liquid nitrogen temperature\",\"authors\":\"I. Sauers, D. James, E. Tuncer, A. Ellis, M. Pace\",\"doi\":\"10.1109/CEIDP.2006.312019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A prototype 5-m triaxial high temperature superconducting (HTS) distribution class cable using a cold dielectric design was tested at high voltage under various conditions including AC, impulse and partial discharge (PD). The dielectric consists of wrapped synthetic tape insulation with liquid nitrogen filling the butt-gaps. In this paper we report on the partial discharge signals in the cable and methods for data analysis. All measurements were made cold in liquid nitrogen. The data will be presented in terms of PD amplitude and energy. Partial discharge signals were observed in the presence of large amounts of background noise due to the inverter circuits of the cryogenic system and these issues will also be discussed.\",\"PeriodicalId\":219099,\"journal\":{\"name\":\"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2006.312019\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2006.312019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

采用冷介质设计的5米三轴高温超导(HTS)配电级电缆样机在交流、冲击和局部放电(PD)等多种高压条件下进行了测试。电介质由包裹的合成绝缘带组成,其中液氮填充对接间隙。本文报道了电缆中的局部放电信号及其分析方法。所有的测量都是在液态氮中进行的。数据将以PD振幅和能量的形式呈现。在低温系统的逆变电路存在大量背景噪声的情况下观察到局部放电信号,这些问题也将被讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Partial discharge measurements in a high temperature superconducting triaxial 5-m model cable at liquid nitrogen temperature
A prototype 5-m triaxial high temperature superconducting (HTS) distribution class cable using a cold dielectric design was tested at high voltage under various conditions including AC, impulse and partial discharge (PD). The dielectric consists of wrapped synthetic tape insulation with liquid nitrogen filling the butt-gaps. In this paper we report on the partial discharge signals in the cable and methods for data analysis. All measurements were made cold in liquid nitrogen. The data will be presented in terms of PD amplitude and energy. Partial discharge signals were observed in the presence of large amounts of background noise due to the inverter circuits of the cryogenic system and these issues will also be discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信