电压不平衡条件下弱电网负荷变化的影响

A. Khan, M. A. Khan, P. Barendse
{"title":"电压不平衡条件下弱电网负荷变化的影响","authors":"A. Khan, M. A. Khan, P. Barendse","doi":"10.1109/ICELMACH.2014.6960413","DOIUrl":null,"url":null,"abstract":"This paper presents the basic principle of a laboratory based weak grid emulator in order to describe the effects of load variation at the point of common coupling (PCC). The impact of these effects is significant and for that a voltage regulation feature has been added to maintain the voltage at the load connection. Design and performance are investigated by introducing unbalanced voltage conditions to test the system's behavior. In case of unbalance, power is injected from the DC link to regulate the voltage at the converter output connected to either passive or an active load. The system has a rating of 1 kW and can handle an output voltage of 50-150% of the nominal voltage peak. A space vector voltage oriented control (VOC) technique is implemented on the converters and the PI controller gains are tuned accordingly. National Instruments (NI) PXI controller is used for the hardware implementation. Voltage unbalance is generated and controlled with the help of dual vector sequence extraction technique.","PeriodicalId":288960,"journal":{"name":"2014 International Conference on Electrical Machines (ICEM)","volume":"114 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Effects of load variation on a weak grid under unbalanced voltage conditions\",\"authors\":\"A. Khan, M. A. Khan, P. Barendse\",\"doi\":\"10.1109/ICELMACH.2014.6960413\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the basic principle of a laboratory based weak grid emulator in order to describe the effects of load variation at the point of common coupling (PCC). The impact of these effects is significant and for that a voltage regulation feature has been added to maintain the voltage at the load connection. Design and performance are investigated by introducing unbalanced voltage conditions to test the system's behavior. In case of unbalance, power is injected from the DC link to regulate the voltage at the converter output connected to either passive or an active load. The system has a rating of 1 kW and can handle an output voltage of 50-150% of the nominal voltage peak. A space vector voltage oriented control (VOC) technique is implemented on the converters and the PI controller gains are tuned accordingly. National Instruments (NI) PXI controller is used for the hardware implementation. Voltage unbalance is generated and controlled with the help of dual vector sequence extraction technique.\",\"PeriodicalId\":288960,\"journal\":{\"name\":\"2014 International Conference on Electrical Machines (ICEM)\",\"volume\":\"114 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Electrical Machines (ICEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICELMACH.2014.6960413\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Electrical Machines (ICEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICELMACH.2014.6960413","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文介绍了基于实验室的弱电网仿真器的基本原理,以描述在共耦合点(PCC)处负载变化的影响。这些影响的影响是显著的,并已添加电压调节功能,以保持电压在负载连接。通过引入不平衡电压条件来测试系统的性能,研究了系统的设计和性能。在不平衡的情况下,从直流链路注入功率来调节连接到无源或有源负载的变换器输出端的电压。该系统额定功率为1kw,可处理标称峰值电压50-150%的输出电压。在变换器上实现了空间矢量电压定向控制(VOC)技术,并相应地调整了PI控制器的增益。硬件实现采用NI (National Instruments) PXI控制器。利用双向量序列提取技术产生和控制电压不平衡。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of load variation on a weak grid under unbalanced voltage conditions
This paper presents the basic principle of a laboratory based weak grid emulator in order to describe the effects of load variation at the point of common coupling (PCC). The impact of these effects is significant and for that a voltage regulation feature has been added to maintain the voltage at the load connection. Design and performance are investigated by introducing unbalanced voltage conditions to test the system's behavior. In case of unbalance, power is injected from the DC link to regulate the voltage at the converter output connected to either passive or an active load. The system has a rating of 1 kW and can handle an output voltage of 50-150% of the nominal voltage peak. A space vector voltage oriented control (VOC) technique is implemented on the converters and the PI controller gains are tuned accordingly. National Instruments (NI) PXI controller is used for the hardware implementation. Voltage unbalance is generated and controlled with the help of dual vector sequence extraction technique.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信