从植入心脏监视器数据提取的心房纤颤率特征

Javier Saiz-Vivó, Mostafa Abdollahpur, L. Mainardi, V. Corino, M. Melis, F. Sandberg
{"title":"从植入心脏监视器数据提取的心房纤颤率特征","authors":"Javier Saiz-Vivó, Mostafa Abdollahpur, L. Mainardi, V. Corino, M. Melis, F. Sandberg","doi":"10.23919/cinc53138.2021.9662826","DOIUrl":null,"url":null,"abstract":"The aim of this study is to characterize atrial fibrillatory rate (AFR) extracted from a cohort of continuously monitored atrial fibrillation (AF) patients as function of episode duration and onset time. The f-wave signal used to compute the AFR was extracted from a single lead ECG strip of the AF episodes stored in an Implantable Cardiac Monitor (ICM) in a cohort of 99 patients. The f-wave signals were obtained from 1400 AF episodes using a spatiotemporal QRST cancellation process and the AFR was estimated as the fundamental frequency of a model fitted to the extracted f-waves. We studied the relationship between AFR and episode duration and episode onset time, respectively. AFR (median (interquartile range)) was significantly lower (p-value<0.05) in short episodes (<20 min) (5.15 (0.66) Hz) than in longer episodes (5.30 (0.74) Hz). AFR was significantly higher for episodes with onset time at night (00-06) (5.34 (0.82) Hz) than for episodes with onset during the day (10-20) (5.21 (0.70) Hz). Significant differences were also found between the relative AFR (ratio between the AFR and the average AFR of the patient) and episode duration (Short: 99.2 (9.3) %; Long: 100.0 (8.9) %). Data extracted from ICMs shows that that nighttime AF onset and longer duration AF episodes are more common in patients with higher AFR.","PeriodicalId":126746,"journal":{"name":"2021 Computing in Cardiology (CinC)","volume":"161 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Atrial Fibrillatory Rate Characterization Extracted from Implanted Cardiac Monitor Data\",\"authors\":\"Javier Saiz-Vivó, Mostafa Abdollahpur, L. Mainardi, V. Corino, M. Melis, F. Sandberg\",\"doi\":\"10.23919/cinc53138.2021.9662826\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this study is to characterize atrial fibrillatory rate (AFR) extracted from a cohort of continuously monitored atrial fibrillation (AF) patients as function of episode duration and onset time. The f-wave signal used to compute the AFR was extracted from a single lead ECG strip of the AF episodes stored in an Implantable Cardiac Monitor (ICM) in a cohort of 99 patients. The f-wave signals were obtained from 1400 AF episodes using a spatiotemporal QRST cancellation process and the AFR was estimated as the fundamental frequency of a model fitted to the extracted f-waves. We studied the relationship between AFR and episode duration and episode onset time, respectively. AFR (median (interquartile range)) was significantly lower (p-value<0.05) in short episodes (<20 min) (5.15 (0.66) Hz) than in longer episodes (5.30 (0.74) Hz). AFR was significantly higher for episodes with onset time at night (00-06) (5.34 (0.82) Hz) than for episodes with onset during the day (10-20) (5.21 (0.70) Hz). Significant differences were also found between the relative AFR (ratio between the AFR and the average AFR of the patient) and episode duration (Short: 99.2 (9.3) %; Long: 100.0 (8.9) %). Data extracted from ICMs shows that that nighttime AF onset and longer duration AF episodes are more common in patients with higher AFR.\",\"PeriodicalId\":126746,\"journal\":{\"name\":\"2021 Computing in Cardiology (CinC)\",\"volume\":\"161 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 Computing in Cardiology (CinC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/cinc53138.2021.9662826\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Computing in Cardiology (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/cinc53138.2021.9662826","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是从一组连续监测的心房颤动(AF)患者中提取心房纤颤率(AFR)作为发作持续时间和发病时间的函数。用于计算AFR的f波信号是从存储在植入式心脏监护仪(ICM)中的AF发作的单导联心电图条中提取的。利用时空QRST对消方法从1400个AF事件中获得f波信号,并将AFR作为与提取的f波拟合的模型的基频估计。我们分别研究了AFR与发作时间和发作时间的关系。短发作(<20 min)的AFR(中位数(四分位数范围))显著低于长发作(5.30 (0.74)Hz) (p值<0.05)(5.15 (0.66)Hz)。夜间(00-06)发作的AFR (5.34 (0.82) Hz)明显高于白天(10-20)发作的AFR (5.21 (0.70) Hz)。相对AFR (AFR与患者平均AFR之比)和发作持续时间(短:99.2 (9.3)%;长:100.0(8.9)%)。从ICMs中提取的数据显示,夜间AF发作和持续时间较长的AF发作在AFR较高的患者中更为常见。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Atrial Fibrillatory Rate Characterization Extracted from Implanted Cardiac Monitor Data
The aim of this study is to characterize atrial fibrillatory rate (AFR) extracted from a cohort of continuously monitored atrial fibrillation (AF) patients as function of episode duration and onset time. The f-wave signal used to compute the AFR was extracted from a single lead ECG strip of the AF episodes stored in an Implantable Cardiac Monitor (ICM) in a cohort of 99 patients. The f-wave signals were obtained from 1400 AF episodes using a spatiotemporal QRST cancellation process and the AFR was estimated as the fundamental frequency of a model fitted to the extracted f-waves. We studied the relationship between AFR and episode duration and episode onset time, respectively. AFR (median (interquartile range)) was significantly lower (p-value<0.05) in short episodes (<20 min) (5.15 (0.66) Hz) than in longer episodes (5.30 (0.74) Hz). AFR was significantly higher for episodes with onset time at night (00-06) (5.34 (0.82) Hz) than for episodes with onset during the day (10-20) (5.21 (0.70) Hz). Significant differences were also found between the relative AFR (ratio between the AFR and the average AFR of the patient) and episode duration (Short: 99.2 (9.3) %; Long: 100.0 (8.9) %). Data extracted from ICMs shows that that nighttime AF onset and longer duration AF episodes are more common in patients with higher AFR.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信