{"title":"永磁同步电机低速反电动势估计方法的比较","authors":"K. Urbanski","doi":"10.1109/MECHATRONIKA.2014.7018232","DOIUrl":null,"url":null,"abstract":"The paper presents a comparison of methods of the back EMFs estimation for the permanent magnets synchronous motor in a case of position estimation at the low speed range. These methods are based on the following structures for back EMF estimation: observer for model of the electrical part of the motor, the observer for the modified correction function and estimation based on the simplified model. Obtained in this way the instantaneous values of the back EMFs, depending on the method of obtaining them, are characterized by different quality and accuracy of the estimated shaft position.","PeriodicalId":430829,"journal":{"name":"Proceedings of the 16th International Conference on Mechatronics - Mechatronika 2014","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Comparison of methods for back EMF estimation at low speed for PMSM drive\",\"authors\":\"K. Urbanski\",\"doi\":\"10.1109/MECHATRONIKA.2014.7018232\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents a comparison of methods of the back EMFs estimation for the permanent magnets synchronous motor in a case of position estimation at the low speed range. These methods are based on the following structures for back EMF estimation: observer for model of the electrical part of the motor, the observer for the modified correction function and estimation based on the simplified model. Obtained in this way the instantaneous values of the back EMFs, depending on the method of obtaining them, are characterized by different quality and accuracy of the estimated shaft position.\",\"PeriodicalId\":430829,\"journal\":{\"name\":\"Proceedings of the 16th International Conference on Mechatronics - Mechatronika 2014\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 16th International Conference on Mechatronics - Mechatronika 2014\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MECHATRONIKA.2014.7018232\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 16th International Conference on Mechatronics - Mechatronika 2014","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MECHATRONIKA.2014.7018232","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparison of methods for back EMF estimation at low speed for PMSM drive
The paper presents a comparison of methods of the back EMFs estimation for the permanent magnets synchronous motor in a case of position estimation at the low speed range. These methods are based on the following structures for back EMF estimation: observer for model of the electrical part of the motor, the observer for the modified correction function and estimation based on the simplified model. Obtained in this way the instantaneous values of the back EMFs, depending on the method of obtaining them, are characterized by different quality and accuracy of the estimated shaft position.