{"title":"多副扬声器对风管ANC系统性能和稳定性的改进","authors":"Liu Huideng, Qiu Arui","doi":"10.1109/ICOSP.2010.5655012","DOIUrl":null,"url":null,"abstract":"A multi-channel duct active noise control(ANC) system is investigated in this paper with both theoretical and experimental studies. An optimized method to minimize the total sound power in a duct is proposed to determine the positions of secondary speakers and error sensors. The validity of theoretical calculation results is proved on a practical duct platform, and the experimental results indicate that remarkable improvements can be achieved on both noise reduction and system stability with the multiple secondary speakers rather than a single secondary speaker.","PeriodicalId":281876,"journal":{"name":"IEEE 10th INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improvement on performance and stability with multiple secondary speakers in duct ANC system\",\"authors\":\"Liu Huideng, Qiu Arui\",\"doi\":\"10.1109/ICOSP.2010.5655012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A multi-channel duct active noise control(ANC) system is investigated in this paper with both theoretical and experimental studies. An optimized method to minimize the total sound power in a duct is proposed to determine the positions of secondary speakers and error sensors. The validity of theoretical calculation results is proved on a practical duct platform, and the experimental results indicate that remarkable improvements can be achieved on both noise reduction and system stability with the multiple secondary speakers rather than a single secondary speaker.\",\"PeriodicalId\":281876,\"journal\":{\"name\":\"IEEE 10th INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE 10th INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICOSP.2010.5655012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 10th INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICOSP.2010.5655012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Improvement on performance and stability with multiple secondary speakers in duct ANC system
A multi-channel duct active noise control(ANC) system is investigated in this paper with both theoretical and experimental studies. An optimized method to minimize the total sound power in a duct is proposed to determine the positions of secondary speakers and error sensors. The validity of theoretical calculation results is proved on a practical duct platform, and the experimental results indicate that remarkable improvements can be achieved on both noise reduction and system stability with the multiple secondary speakers rather than a single secondary speaker.