探索900纳米以上的多光谱虹膜识别

A. Ross, R. Pasula, L. Hornak
{"title":"探索900纳米以上的多光谱虹膜识别","authors":"A. Ross, R. Pasula, L. Hornak","doi":"10.1109/BTAS.2009.5339072","DOIUrl":null,"url":null,"abstract":"Most iris recognition systems acquire images of the eye in the 700nm–900nm range of the electromagnetic spectrum. In this work, the iris is examined at wavelengths beyond 900nm. The purpose is to understand the iris structure at longer wavelengths and to determine the possibility of performing cross-spectral iris matching. An acquisition system is first designed for imaging the iris at narrow spectral bands in the 950 nm–1650 nm range. Next, the left and right images of the iris are acquired from 25 subjects in order to conduct the analysis. Finally, the possibility of performing cross-spectral matching and multispectral fusion at the match score level is investigated. Experimental results suggest: (a) the feasibility of acquiring iris images in wavelengths beyond 900nm using InGaAs detectors; (b) the possibility of observing different structures in the iris anatomy at various wavelengths; and (c) the potential of performing cross-spectral matching and multispectral fusion for enhanced iris recognition.","PeriodicalId":325900,"journal":{"name":"2009 IEEE 3rd International Conference on Biometrics: Theory, Applications, and Systems","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"82","resultStr":"{\"title\":\"Exploring multispectral iris recognition beyond 900nm\",\"authors\":\"A. Ross, R. Pasula, L. Hornak\",\"doi\":\"10.1109/BTAS.2009.5339072\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Most iris recognition systems acquire images of the eye in the 700nm–900nm range of the electromagnetic spectrum. In this work, the iris is examined at wavelengths beyond 900nm. The purpose is to understand the iris structure at longer wavelengths and to determine the possibility of performing cross-spectral iris matching. An acquisition system is first designed for imaging the iris at narrow spectral bands in the 950 nm–1650 nm range. Next, the left and right images of the iris are acquired from 25 subjects in order to conduct the analysis. Finally, the possibility of performing cross-spectral matching and multispectral fusion at the match score level is investigated. Experimental results suggest: (a) the feasibility of acquiring iris images in wavelengths beyond 900nm using InGaAs detectors; (b) the possibility of observing different structures in the iris anatomy at various wavelengths; and (c) the potential of performing cross-spectral matching and multispectral fusion for enhanced iris recognition.\",\"PeriodicalId\":325900,\"journal\":{\"name\":\"2009 IEEE 3rd International Conference on Biometrics: Theory, Applications, and Systems\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"82\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE 3rd International Conference on Biometrics: Theory, Applications, and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BTAS.2009.5339072\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE 3rd International Conference on Biometrics: Theory, Applications, and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BTAS.2009.5339072","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 82

摘要

大多数虹膜识别系统在电磁波谱的700nm-900nm范围内获取眼睛的图像。在这项工作中,虹膜的波长超过900纳米。目的是了解较长波长的虹膜结构,并确定进行跨光谱虹膜匹配的可能性。首先设计了一种用于在950 nm - 1650 nm范围内对虹膜进行窄光谱成像的采集系统。接下来,采集25名受试者的左右虹膜图像进行分析。最后,研究了在匹配分数水平上进行跨光谱匹配和多光谱融合的可能性。实验结果表明:(a)利用InGaAs探测器获取900nm以上波长虹膜图像的可行性;(b)在不同波长下观察虹膜解剖结构不同的可能性;(c)进行交叉光谱匹配和多光谱融合以增强虹膜识别的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Exploring multispectral iris recognition beyond 900nm
Most iris recognition systems acquire images of the eye in the 700nm–900nm range of the electromagnetic spectrum. In this work, the iris is examined at wavelengths beyond 900nm. The purpose is to understand the iris structure at longer wavelengths and to determine the possibility of performing cross-spectral iris matching. An acquisition system is first designed for imaging the iris at narrow spectral bands in the 950 nm–1650 nm range. Next, the left and right images of the iris are acquired from 25 subjects in order to conduct the analysis. Finally, the possibility of performing cross-spectral matching and multispectral fusion at the match score level is investigated. Experimental results suggest: (a) the feasibility of acquiring iris images in wavelengths beyond 900nm using InGaAs detectors; (b) the possibility of observing different structures in the iris anatomy at various wavelengths; and (c) the potential of performing cross-spectral matching and multispectral fusion for enhanced iris recognition.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信