在低运行负荷下检测和预测电弧闪光事件

Ross Kennedy
{"title":"在低运行负荷下检测和预测电弧闪光事件","authors":"Ross Kennedy","doi":"10.1109/PCICON.2014.6961907","DOIUrl":null,"url":null,"abstract":"One of the primary causes of electrical arc flash incidents is compromised joints. The accepted “Best Practice” has been periodic thermal scans (typically annual). However, this does not overcome critical issues e.g. workers remain exposed to risks, it's only an annual “snapshot”, often taken at a time not reflecting the most critical operating phases, or conversely at such a critical instant that it may actually cause the incident, and the measurement is taken externally requiring operator correlation to the true internal temperature. This is of particular relevance to the oil & gas industry where dual power feeds, each operating at low operational load (typically below 40%), is the norm.","PeriodicalId":264800,"journal":{"name":"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Detecting and predicting arc flash events at low operational loads\",\"authors\":\"Ross Kennedy\",\"doi\":\"10.1109/PCICON.2014.6961907\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One of the primary causes of electrical arc flash incidents is compromised joints. The accepted “Best Practice” has been periodic thermal scans (typically annual). However, this does not overcome critical issues e.g. workers remain exposed to risks, it's only an annual “snapshot”, often taken at a time not reflecting the most critical operating phases, or conversely at such a critical instant that it may actually cause the incident, and the measurement is taken externally requiring operator correlation to the true internal temperature. This is of particular relevance to the oil & gas industry where dual power feeds, each operating at low operational load (typically below 40%), is the norm.\",\"PeriodicalId\":264800,\"journal\":{\"name\":\"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCICON.2014.6961907\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCICON.2014.6961907","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

电弧闪光事故的主要原因之一是接头受损。公认的“最佳实践”是定期热扫描(通常是每年一次)。然而,这并不能克服关键问题,例如工人仍然面临风险,这只是每年的“快照”,通常在不反映最关键的操作阶段的时候拍摄,或者相反,在这样一个关键的时刻,它实际上可能导致事故,并且测量是在外部进行的,需要操作员与真实的内部温度相关联。这对于油气行业来说尤其重要,因为在该行业中,双馈电源在低运行负荷(通常低于40%)下运行是常态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Detecting and predicting arc flash events at low operational loads
One of the primary causes of electrical arc flash incidents is compromised joints. The accepted “Best Practice” has been periodic thermal scans (typically annual). However, this does not overcome critical issues e.g. workers remain exposed to risks, it's only an annual “snapshot”, often taken at a time not reflecting the most critical operating phases, or conversely at such a critical instant that it may actually cause the incident, and the measurement is taken externally requiring operator correlation to the true internal temperature. This is of particular relevance to the oil & gas industry where dual power feeds, each operating at low operational load (typically below 40%), is the norm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信