P. M. Licla, E. Laura Bravo, G. Kemper, J. L. Villalobos, C. del Carpio, C. D. Aliaga
{"title":"一种光疗灯有效照射区域辐照度分布方法","authors":"P. M. Licla, E. Laura Bravo, G. Kemper, J. L. Villalobos, C. del Carpio, C. D. Aliaga","doi":"10.1109/INTERCON.2018.8526373","DOIUrl":null,"url":null,"abstract":"Since the American Academy of Pediatrics (AAP) and the International Electrotechnical Commission (IEC) upheld the criterion of effective irradiated area as part of design standards for neonatal phototherapy lamps, it has become a very important factor to guarantee according to a certain method a uniform distribution of irradiance besides an effective phototherapy treatment. The objective of this article is show through an analytical method the most uniform distribution of irradiance with a matrix of blue LEDs. Besides the proposed design is simulated in a specialized software and evaluated experimentally for its respective validation. Irradiance tests are included with a calibrated radiometer.","PeriodicalId":305576,"journal":{"name":"2018 IEEE XXV International Conference on Electronics, Electrical Engineering and Computing (INTERCON)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A Method of Irradiance Distributing Over an Effective Irradiated Area for Phototherapy Lamps\",\"authors\":\"P. M. Licla, E. Laura Bravo, G. Kemper, J. L. Villalobos, C. del Carpio, C. D. Aliaga\",\"doi\":\"10.1109/INTERCON.2018.8526373\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Since the American Academy of Pediatrics (AAP) and the International Electrotechnical Commission (IEC) upheld the criterion of effective irradiated area as part of design standards for neonatal phototherapy lamps, it has become a very important factor to guarantee according to a certain method a uniform distribution of irradiance besides an effective phototherapy treatment. The objective of this article is show through an analytical method the most uniform distribution of irradiance with a matrix of blue LEDs. Besides the proposed design is simulated in a specialized software and evaluated experimentally for its respective validation. Irradiance tests are included with a calibrated radiometer.\",\"PeriodicalId\":305576,\"journal\":{\"name\":\"2018 IEEE XXV International Conference on Electronics, Electrical Engineering and Computing (INTERCON)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE XXV International Conference on Electronics, Electrical Engineering and Computing (INTERCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTERCON.2018.8526373\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE XXV International Conference on Electronics, Electrical Engineering and Computing (INTERCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTERCON.2018.8526373","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
摘要
自从美国儿科学会(American Academy of Pediatrics, AAP)和国际电工委员会(International Electrotechnical Commission, IEC)将有效照射面积作为新生儿光疗灯设计标准的一部分以来,除了进行有效的光疗治疗外,按照一定的方法保证辐照度均匀分布已成为一个非常重要的因素。本文的目的是通过一种分析方法来显示蓝光led矩阵中最均匀的辐照度分布。此外,在专门的软件中对所提出的设计进行了仿真,并对其各自的有效性进行了实验评估。辐照度测试包括一个校准辐射计。
A Method of Irradiance Distributing Over an Effective Irradiated Area for Phototherapy Lamps
Since the American Academy of Pediatrics (AAP) and the International Electrotechnical Commission (IEC) upheld the criterion of effective irradiated area as part of design standards for neonatal phototherapy lamps, it has become a very important factor to guarantee according to a certain method a uniform distribution of irradiance besides an effective phototherapy treatment. The objective of this article is show through an analytical method the most uniform distribution of irradiance with a matrix of blue LEDs. Besides the proposed design is simulated in a specialized software and evaluated experimentally for its respective validation. Irradiance tests are included with a calibrated radiometer.