{"title":"基于区间算法的非线性动态系统故障隔离方法","authors":"Ze-tao Li, B. Dahhou, Qiao Li","doi":"10.1109/CCDC.2012.6243015","DOIUrl":null,"url":null,"abstract":"In this work interval arithmetic is used for the calculation of interval envelopes in the parameter interval based fault isolation method. Thanks the advantage of interval arithmetic of without dependence on the monotonic of model parameters, the application of the parameter interval based fault isolation method can be extended to multi-parameters fault.","PeriodicalId":345790,"journal":{"name":"2012 24th Chinese Control and Decision Conference (CCDC)","volume":"71 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A fault isolation method using interval arithmetic for nonlinear dynamic systems\",\"authors\":\"Ze-tao Li, B. Dahhou, Qiao Li\",\"doi\":\"10.1109/CCDC.2012.6243015\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work interval arithmetic is used for the calculation of interval envelopes in the parameter interval based fault isolation method. Thanks the advantage of interval arithmetic of without dependence on the monotonic of model parameters, the application of the parameter interval based fault isolation method can be extended to multi-parameters fault.\",\"PeriodicalId\":345790,\"journal\":{\"name\":\"2012 24th Chinese Control and Decision Conference (CCDC)\",\"volume\":\"71 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 24th Chinese Control and Decision Conference (CCDC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCDC.2012.6243015\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 24th Chinese Control and Decision Conference (CCDC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCDC.2012.6243015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A fault isolation method using interval arithmetic for nonlinear dynamic systems
In this work interval arithmetic is used for the calculation of interval envelopes in the parameter interval based fault isolation method. Thanks the advantage of interval arithmetic of without dependence on the monotonic of model parameters, the application of the parameter interval based fault isolation method can be extended to multi-parameters fault.