A. Phenis, A. Halterman, Andrew Nichols, Alicia Maccarrone, J. Mudge
{"title":"一种超宽带、宽视场推扫成像辐射计的设计","authors":"A. Phenis, A. Halterman, Andrew Nichols, Alicia Maccarrone, J. Mudge","doi":"10.1117/12.2603670","DOIUrl":null,"url":null,"abstract":"The design of a push-broom radiometer operating from 0.2 μm to greater than 50 μm with a FOR > 120° is presented. The challenge is to design a WFOV radiometer with high accuracy and low uncertainty. This paper will present the results of an effort to design an ultra-broadband WFOV imaging radiometer, while balancing conditions that can impact the radiometric accuracy of the instrument. This system is further complicated by implementation of a single detector array that is sensitive to light over this very broad spectral range.","PeriodicalId":386109,"journal":{"name":"International Optical Design Conference","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design of an ultra-broadband, wide-field-of-view push-broom imaging radiometer\",\"authors\":\"A. Phenis, A. Halterman, Andrew Nichols, Alicia Maccarrone, J. Mudge\",\"doi\":\"10.1117/12.2603670\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The design of a push-broom radiometer operating from 0.2 μm to greater than 50 μm with a FOR > 120° is presented. The challenge is to design a WFOV radiometer with high accuracy and low uncertainty. This paper will present the results of an effort to design an ultra-broadband WFOV imaging radiometer, while balancing conditions that can impact the radiometric accuracy of the instrument. This system is further complicated by implementation of a single detector array that is sensitive to light over this very broad spectral range.\",\"PeriodicalId\":386109,\"journal\":{\"name\":\"International Optical Design Conference\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Optical Design Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2603670\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Optical Design Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2603670","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design of an ultra-broadband, wide-field-of-view push-broom imaging radiometer
The design of a push-broom radiometer operating from 0.2 μm to greater than 50 μm with a FOR > 120° is presented. The challenge is to design a WFOV radiometer with high accuracy and low uncertainty. This paper will present the results of an effort to design an ultra-broadband WFOV imaging radiometer, while balancing conditions that can impact the radiometric accuracy of the instrument. This system is further complicated by implementation of a single detector array that is sensitive to light over this very broad spectral range.