{"title":"欧洲散裂源速调管加速器中压直流和交流电源分析","authors":"J. Voss, H. Stagge, R. Dedoncker","doi":"10.1109/PEAC.2014.7038076","DOIUrl":null,"url":null,"abstract":"The European Spallation Source is a planned research facility in Lund-Sweden for scientific research using particle accelerators. In the facility protons will be accelerated in a pulsed pattern and collide with a heavy metal target. Due to the impact of the protons intense pulses of neutrons are emitted. These neutrons are led to experimental stations, where research on materials is executed. A total power of 25-40 MW will be needed when the beam is in operation. Because the linear accelerator beams the protons in a 14 Hz pulse pattern flicker and other distortion may impact on the transmission grid. In the following paper the focus lies on converters and control design to lower the grid impact. The internal grid is analyzed to improve the availability. Finally ac- and dc-distribution grids are compared.","PeriodicalId":309780,"journal":{"name":"2014 International Power Electronics and Application Conference and Exposition","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of medium-voltage DC and AC supply for klystron accelerators at the European Spallation source\",\"authors\":\"J. Voss, H. Stagge, R. Dedoncker\",\"doi\":\"10.1109/PEAC.2014.7038076\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The European Spallation Source is a planned research facility in Lund-Sweden for scientific research using particle accelerators. In the facility protons will be accelerated in a pulsed pattern and collide with a heavy metal target. Due to the impact of the protons intense pulses of neutrons are emitted. These neutrons are led to experimental stations, where research on materials is executed. A total power of 25-40 MW will be needed when the beam is in operation. Because the linear accelerator beams the protons in a 14 Hz pulse pattern flicker and other distortion may impact on the transmission grid. In the following paper the focus lies on converters and control design to lower the grid impact. The internal grid is analyzed to improve the availability. Finally ac- and dc-distribution grids are compared.\",\"PeriodicalId\":309780,\"journal\":{\"name\":\"2014 International Power Electronics and Application Conference and Exposition\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Power Electronics and Application Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEAC.2014.7038076\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Power Electronics and Application Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEAC.2014.7038076","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of medium-voltage DC and AC supply for klystron accelerators at the European Spallation source
The European Spallation Source is a planned research facility in Lund-Sweden for scientific research using particle accelerators. In the facility protons will be accelerated in a pulsed pattern and collide with a heavy metal target. Due to the impact of the protons intense pulses of neutrons are emitted. These neutrons are led to experimental stations, where research on materials is executed. A total power of 25-40 MW will be needed when the beam is in operation. Because the linear accelerator beams the protons in a 14 Hz pulse pattern flicker and other distortion may impact on the transmission grid. In the following paper the focus lies on converters and control design to lower the grid impact. The internal grid is analyzed to improve the availability. Finally ac- and dc-distribution grids are compared.