核电厂模糊控制器

P. Ramaswamy, R. Edwards, K.Y. Lee
{"title":"核电厂模糊控制器","authors":"P. Ramaswamy, R. Edwards, K.Y. Lee","doi":"10.1109/ANN.1993.264354","DOIUrl":null,"url":null,"abstract":"The design and evaluation by simulation of an automatically-tuned fuzzy logic controller is presented. A method to automate the tuning process using a simplified Kalman filter approach is presented for the fuzzy logic controller to track a suitable reference trajectory. An optimal controller's response is used as a reference trajectory to determine automatically the rules for the fuzzy logic controller. To demonstrate the robustness of this design approach, a nonlinear six delayed neutron group plant is controlled using a fuzzy logic controller that utilizes estimated reactor temperatures from a one delayed neutron group observer. The fuzzy logic controller displayed good stability and performance robustness characteristics for a wide range of operation.<<ETX>>","PeriodicalId":121897,"journal":{"name":"[1993] Proceedings of the Second International Forum on Applications of Neural Networks to Power Systems","volume":"13 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Fuzzy logic controller for nuclear power plant\",\"authors\":\"P. Ramaswamy, R. Edwards, K.Y. Lee\",\"doi\":\"10.1109/ANN.1993.264354\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The design and evaluation by simulation of an automatically-tuned fuzzy logic controller is presented. A method to automate the tuning process using a simplified Kalman filter approach is presented for the fuzzy logic controller to track a suitable reference trajectory. An optimal controller's response is used as a reference trajectory to determine automatically the rules for the fuzzy logic controller. To demonstrate the robustness of this design approach, a nonlinear six delayed neutron group plant is controlled using a fuzzy logic controller that utilizes estimated reactor temperatures from a one delayed neutron group observer. The fuzzy logic controller displayed good stability and performance robustness characteristics for a wide range of operation.<<ETX>>\",\"PeriodicalId\":121897,\"journal\":{\"name\":\"[1993] Proceedings of the Second International Forum on Applications of Neural Networks to Power Systems\",\"volume\":\"13 5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-04-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1993] Proceedings of the Second International Forum on Applications of Neural Networks to Power Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ANN.1993.264354\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1993] Proceedings of the Second International Forum on Applications of Neural Networks to Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ANN.1993.264354","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

提出了一种自整定模糊控制器的设计和仿真评价方法。提出了一种利用简化的卡尔曼滤波方法实现自动调谐的方法,使模糊控制器能够跟踪合适的参考轨迹。将最优控制器的响应作为参考轨迹,自动确定模糊控制器的规则。为了证明这种设计方法的鲁棒性,使用模糊逻辑控制器控制一个非线性六延迟中子群装置,该控制器利用从一个延迟中子群观测器估计的反应堆温度。该模糊控制器具有良好的稳定性和性能鲁棒性,适用于大范围的工作
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fuzzy logic controller for nuclear power plant
The design and evaluation by simulation of an automatically-tuned fuzzy logic controller is presented. A method to automate the tuning process using a simplified Kalman filter approach is presented for the fuzzy logic controller to track a suitable reference trajectory. An optimal controller's response is used as a reference trajectory to determine automatically the rules for the fuzzy logic controller. To demonstrate the robustness of this design approach, a nonlinear six delayed neutron group plant is controlled using a fuzzy logic controller that utilizes estimated reactor temperatures from a one delayed neutron group observer. The fuzzy logic controller displayed good stability and performance robustness characteristics for a wide range of operation.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信