H. E. Sueta, M. Shigihara, L. E. Caires, J. Grimoni, D. Leite
{"title":"天然LPS对钢筋混凝土柱的连续性试验","authors":"H. E. Sueta, M. Shigihara, L. E. Caires, J. Grimoni, D. Leite","doi":"10.1109/SIPDA.2011.6088429","DOIUrl":null,"url":null,"abstract":"In the present paper, we show results concerning measurements as well as several computer simulations in relation to the implementation of standards I EC 62305 [2] [3] [4] [5] and the Brazilian NBR 5419 [1] with regard specifically to the use of structure natural components, such as vertical and horizontal columns, used as a means of current flow in the incidence of a lightning discharge.","PeriodicalId":277573,"journal":{"name":"2011 International Symposium on Lightning Protection","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continuity tests in reinforced concrete columns for natural LPS\",\"authors\":\"H. E. Sueta, M. Shigihara, L. E. Caires, J. Grimoni, D. Leite\",\"doi\":\"10.1109/SIPDA.2011.6088429\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the present paper, we show results concerning measurements as well as several computer simulations in relation to the implementation of standards I EC 62305 [2] [3] [4] [5] and the Brazilian NBR 5419 [1] with regard specifically to the use of structure natural components, such as vertical and horizontal columns, used as a means of current flow in the incidence of a lightning discharge.\",\"PeriodicalId\":277573,\"journal\":{\"name\":\"2011 International Symposium on Lightning Protection\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Symposium on Lightning Protection\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIPDA.2011.6088429\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Symposium on Lightning Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2011.6088429","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Continuity tests in reinforced concrete columns for natural LPS
In the present paper, we show results concerning measurements as well as several computer simulations in relation to the implementation of standards I EC 62305 [2] [3] [4] [5] and the Brazilian NBR 5419 [1] with regard specifically to the use of structure natural components, such as vertical and horizontal columns, used as a means of current flow in the incidence of a lightning discharge.