压力测试和动态心电图系统的信号平均

H. Palacios, D. Rodríguez, J. Castro, V. Gomez, J. Jorquera, T. Magdhal
{"title":"压力测试和动态心电图系统的信号平均","authors":"H. Palacios, D. Rodríguez, J. Castro, V. Gomez, J. Jorquera, T. Magdhal","doi":"10.1109/COLLOQ.1990.152786","DOIUrl":null,"url":null,"abstract":"A signal averaging technique is presented as a high quality alternative for filtering and cleaning ECG signals. A basic mathematical approach is first presented, with emphasis on the bandwidth reduction due to imperfect synchronism, when the QRS complex and R wave peak are used for synchronizing and alignment. A very reliable method is presented, especially designed for noisy ECG signals; in this method several thresholds are generated, based on the history of the successive cycles; thresholds for the amplitude of high pass filtered ECG signals and their first derivatives are generated in an adaptive and stable way. Finally, results are shown for several typical cases, including static averaging and dynamic real-time averaging.<<ETX>>","PeriodicalId":432127,"journal":{"name":"Proceedings of the 1990 IEEE Colloquium in South America","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Signal averaging in stress test and Holter systems\",\"authors\":\"H. Palacios, D. Rodríguez, J. Castro, V. Gomez, J. Jorquera, T. Magdhal\",\"doi\":\"10.1109/COLLOQ.1990.152786\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A signal averaging technique is presented as a high quality alternative for filtering and cleaning ECG signals. A basic mathematical approach is first presented, with emphasis on the bandwidth reduction due to imperfect synchronism, when the QRS complex and R wave peak are used for synchronizing and alignment. A very reliable method is presented, especially designed for noisy ECG signals; in this method several thresholds are generated, based on the history of the successive cycles; thresholds for the amplitude of high pass filtered ECG signals and their first derivatives are generated in an adaptive and stable way. Finally, results are shown for several typical cases, including static averaging and dynamic real-time averaging.<<ETX>>\",\"PeriodicalId\":432127,\"journal\":{\"name\":\"Proceedings of the 1990 IEEE Colloquium in South America\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1990 IEEE Colloquium in South America\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/COLLOQ.1990.152786\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1990 IEEE Colloquium in South America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COLLOQ.1990.152786","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种信号平均技术作为滤波和清洗心电信号的高质量替代方案。首先提出了一种基本的数学方法,重点研究了当使用QRS复合体和R波峰进行同步和对准时,由于不完全同步而导致的带宽减少。针对有噪声的心电信号,提出了一种非常可靠的方法;在该方法中,根据连续周期的历史生成若干阈值;高通滤波后的心电信号及其一阶导数的幅值阈值自适应稳定生成。最后,给出了静态平均和动态实时平均几个典型实例的计算结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Signal averaging in stress test and Holter systems
A signal averaging technique is presented as a high quality alternative for filtering and cleaning ECG signals. A basic mathematical approach is first presented, with emphasis on the bandwidth reduction due to imperfect synchronism, when the QRS complex and R wave peak are used for synchronizing and alignment. A very reliable method is presented, especially designed for noisy ECG signals; in this method several thresholds are generated, based on the history of the successive cycles; thresholds for the amplitude of high pass filtered ECG signals and their first derivatives are generated in an adaptive and stable way. Finally, results are shown for several typical cases, including static averaging and dynamic real-time averaging.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信