M. Singh, Akhilesh Gupta, Salony Permanand, U. Singh, O. P. Singh, Yong Hoon Kim, Ashish Kumar Singh
{"title":"用于心肺传感的微波多普勒雷达系统建模与信号处理","authors":"M. Singh, Akhilesh Gupta, Salony Permanand, U. Singh, O. P. Singh, Yong Hoon Kim, Ashish Kumar Singh","doi":"10.1109/ICSPCOM.2015.7150652","DOIUrl":null,"url":null,"abstract":"In this paper, we present the modeling, simulation and signal processing of Doppler radar for heart beat and reparation sensing. Distance dependency of accuracy of heart and respiration signal from radar output is investigated and verified through simulation. The model is experimentally validated with commercially available motion detector DNO-341. The based band signal containing respiration and heartbeat signatures are low-pass filtered (0.7 Hz) for the respiration and band-pass filtered (0.9-2.5 Hz) for the heart signal. The estimated heart beat per minute and peak-peak interval is verified with result obtained from standard ECG measurement.","PeriodicalId":318875,"journal":{"name":"2015 International Conference on Signal Processing and Communication (ICSC)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"System modeling and signal processing of microwave Doppler radar for cardiopulmonary sensing\",\"authors\":\"M. Singh, Akhilesh Gupta, Salony Permanand, U. Singh, O. P. Singh, Yong Hoon Kim, Ashish Kumar Singh\",\"doi\":\"10.1109/ICSPCOM.2015.7150652\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we present the modeling, simulation and signal processing of Doppler radar for heart beat and reparation sensing. Distance dependency of accuracy of heart and respiration signal from radar output is investigated and verified through simulation. The model is experimentally validated with commercially available motion detector DNO-341. The based band signal containing respiration and heartbeat signatures are low-pass filtered (0.7 Hz) for the respiration and band-pass filtered (0.9-2.5 Hz) for the heart signal. The estimated heart beat per minute and peak-peak interval is verified with result obtained from standard ECG measurement.\",\"PeriodicalId\":318875,\"journal\":{\"name\":\"2015 International Conference on Signal Processing and Communication (ICSC)\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-03-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Signal Processing and Communication (ICSC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSPCOM.2015.7150652\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Signal Processing and Communication (ICSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSPCOM.2015.7150652","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
System modeling and signal processing of microwave Doppler radar for cardiopulmonary sensing
In this paper, we present the modeling, simulation and signal processing of Doppler radar for heart beat and reparation sensing. Distance dependency of accuracy of heart and respiration signal from radar output is investigated and verified through simulation. The model is experimentally validated with commercially available motion detector DNO-341. The based band signal containing respiration and heartbeat signatures are low-pass filtered (0.7 Hz) for the respiration and band-pass filtered (0.9-2.5 Hz) for the heart signal. The estimated heart beat per minute and peak-peak interval is verified with result obtained from standard ECG measurement.