Hang Lan, Chunhong Chen, Chao Fang, Jiahao Chen, Yulan Lin
{"title":"基于模拟相关器的生物雷达研究","authors":"Hang Lan, Chunhong Chen, Chao Fang, Jiahao Chen, Yulan Lin","doi":"10.1109/IMBIOC.2019.8777923","DOIUrl":null,"url":null,"abstract":"This paper presents a 5.75 GHz high-resolution continuous wave Doppler bioradar system based on the analog correlator. It is used to detect the breathing and heartbeat signals of a stationary human body. To reduce the power consumption of the system, the quadrature demodulation receiver is replaced by the analog correlator to generate the quadrature baseband signal. A radio frequency leakage cancellation module based on the six-port network is used at the front end to improve the detection sensitivity and the Tx-Rx isolation. The results show that the bioradar can accurately measure the heartbeat and respiratory rates at a distance of 1.5 meters.","PeriodicalId":171472,"journal":{"name":"2019 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)","volume":"164 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Research on a Bioradar Based on the Analog Correlator\",\"authors\":\"Hang Lan, Chunhong Chen, Chao Fang, Jiahao Chen, Yulan Lin\",\"doi\":\"10.1109/IMBIOC.2019.8777923\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a 5.75 GHz high-resolution continuous wave Doppler bioradar system based on the analog correlator. It is used to detect the breathing and heartbeat signals of a stationary human body. To reduce the power consumption of the system, the quadrature demodulation receiver is replaced by the analog correlator to generate the quadrature baseband signal. A radio frequency leakage cancellation module based on the six-port network is used at the front end to improve the detection sensitivity and the Tx-Rx isolation. The results show that the bioradar can accurately measure the heartbeat and respiratory rates at a distance of 1.5 meters.\",\"PeriodicalId\":171472,\"journal\":{\"name\":\"2019 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)\",\"volume\":\"164 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMBIOC.2019.8777923\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMBIOC.2019.8777923","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research on a Bioradar Based on the Analog Correlator
This paper presents a 5.75 GHz high-resolution continuous wave Doppler bioradar system based on the analog correlator. It is used to detect the breathing and heartbeat signals of a stationary human body. To reduce the power consumption of the system, the quadrature demodulation receiver is replaced by the analog correlator to generate the quadrature baseband signal. A radio frequency leakage cancellation module based on the six-port network is used at the front end to improve the detection sensitivity and the Tx-Rx isolation. The results show that the bioradar can accurately measure the heartbeat and respiratory rates at a distance of 1.5 meters.