室内相对湿度测量传感器读数的误差和均匀性评定

S. Zaharieva, I. Stoev, A. Borodzhieva, Teodora Petrova
{"title":"室内相对湿度测量传感器读数的误差和均匀性评定","authors":"S. Zaharieva, I. Stoev, A. Borodzhieva, Teodora Petrova","doi":"10.1109/INFOTEH57020.2023.10094132","DOIUrl":null,"url":null,"abstract":"An electronic system for providing comfortable conditions in a room based on the Internet of Things has been developed, which measures temperature, relative humidity, barometric pressure and illumination. The object of statistical evaluation is the relative humidity sensors, which are positioned inside the room and are thirty-two in number, to reserve and prevent the loss of data. The data for the relative humidity from the sensors are recorded twenty-four hours, every minute. Since the reading period is too long, the use of calibrated relative humidity meters is financially uneconomical. This necessitates the implementation of the algorithm of work of the developed electronic system of two statistical approaches to estimate the gross errors and the synchronicity of the readings between the available sensors at a specific point. Thus, if one of the sensors stops reading or if its readings differ significantly from those of the others, the sensor is ignored.","PeriodicalId":287923,"journal":{"name":"2023 22nd International Symposium INFOTEH-JAHORINA (INFOTEH)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Assessment of Gross Errors and Uniformity of Readings of Sensors for Relative Humidity Measurement in Indoor Premises\",\"authors\":\"S. Zaharieva, I. Stoev, A. Borodzhieva, Teodora Petrova\",\"doi\":\"10.1109/INFOTEH57020.2023.10094132\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An electronic system for providing comfortable conditions in a room based on the Internet of Things has been developed, which measures temperature, relative humidity, barometric pressure and illumination. The object of statistical evaluation is the relative humidity sensors, which are positioned inside the room and are thirty-two in number, to reserve and prevent the loss of data. The data for the relative humidity from the sensors are recorded twenty-four hours, every minute. Since the reading period is too long, the use of calibrated relative humidity meters is financially uneconomical. This necessitates the implementation of the algorithm of work of the developed electronic system of two statistical approaches to estimate the gross errors and the synchronicity of the readings between the available sensors at a specific point. Thus, if one of the sensors stops reading or if its readings differ significantly from those of the others, the sensor is ignored.\",\"PeriodicalId\":287923,\"journal\":{\"name\":\"2023 22nd International Symposium INFOTEH-JAHORINA (INFOTEH)\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 22nd International Symposium INFOTEH-JAHORINA (INFOTEH)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INFOTEH57020.2023.10094132\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 22nd International Symposium INFOTEH-JAHORINA (INFOTEH)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INFOTEH57020.2023.10094132","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

开发了一种基于物联网的室内舒适电子系统,可以测量温度、相对湿度、气压和照度。统计评估的对象是相对湿度传感器,这些相对湿度传感器放置在房间内,数量为32个,用于保留和防止数据丢失。来自传感器的相对湿度数据是24小时每分钟记录的。由于读数周期太长,使用经校准的相对湿度计在经济上是不经济的。这就需要采用已开发的电子系统的两种统计方法的工作算法来估计在某一点上可用的传感器之间的读数的严重误差和同步性。因此,如果其中一个传感器停止读取,或者其读数与其他传感器的读数明显不同,则忽略该传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of Gross Errors and Uniformity of Readings of Sensors for Relative Humidity Measurement in Indoor Premises
An electronic system for providing comfortable conditions in a room based on the Internet of Things has been developed, which measures temperature, relative humidity, barometric pressure and illumination. The object of statistical evaluation is the relative humidity sensors, which are positioned inside the room and are thirty-two in number, to reserve and prevent the loss of data. The data for the relative humidity from the sensors are recorded twenty-four hours, every minute. Since the reading period is too long, the use of calibrated relative humidity meters is financially uneconomical. This necessitates the implementation of the algorithm of work of the developed electronic system of two statistical approaches to estimate the gross errors and the synchronicity of the readings between the available sensors at a specific point. Thus, if one of the sensors stops reading or if its readings differ significantly from those of the others, the sensor is ignored.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信