H. Chan, K. Chiang, J. Gardner
{"title":"用于超声功率测量的偏振光纤传感器","authors":"H. Chan, K. Chiang, J. Gardner","doi":"10.1109/ULTSYM.1988.49447","DOIUrl":null,"url":null,"abstract":"A polarimetric fiber-optic sensor using a polarization-maintaining fiber is described. The principle of the sensor is based on the detection of ultrasonically induced birefringence in the fiber. Its response to continuous and pulsed ultrasound at different frequencies and different power levels is investigated. The beam profiles measured by this sensor are compared with those measured using a PVDF (polyvinylidene fluoride) hydrophone. The sensor output is observed to be a linear function of the square root of the total acoustic power measured using a radiation force balance. The application of this sensor to the characterization of medical ultrasonic transducers is also discussed.<<ETX>>","PeriodicalId":263198,"journal":{"name":"IEEE 1988 Ultrasonics Symposium Proceedings.","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Polarimetric optical fiber sensor for ultrasonic power measurement\",\"authors\":\"H. Chan, K. Chiang, J. Gardner\",\"doi\":\"10.1109/ULTSYM.1988.49447\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A polarimetric fiber-optic sensor using a polarization-maintaining fiber is described. The principle of the sensor is based on the detection of ultrasonically induced birefringence in the fiber. Its response to continuous and pulsed ultrasound at different frequencies and different power levels is investigated. The beam profiles measured by this sensor are compared with those measured using a PVDF (polyvinylidene fluoride) hydrophone. The sensor output is observed to be a linear function of the square root of the total acoustic power measured using a radiation force balance. The application of this sensor to the characterization of medical ultrasonic transducers is also discussed.<<ETX>>\",\"PeriodicalId\":263198,\"journal\":{\"name\":\"IEEE 1988 Ultrasonics Symposium Proceedings.\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE 1988 Ultrasonics Symposium Proceedings.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1988.49447\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 1988 Ultrasonics Symposium Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1988.49447","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

介绍了一种使用保偏光纤的偏振光纤传感器。该传感器的工作原理是基于对光纤中超声诱导双折射的检测。研究了其对不同频率、不同功率的连续超声和脉冲超声的响应。用该传感器测量的光束轮廓与用PVDF(聚偏氟乙烯)水听器测量的光束轮廓进行了比较。观察到传感器输出是使用辐射力平衡测量的总声功率的平方根的线性函数。讨论了该传感器在医用超声换能器表征中的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Polarimetric optical fiber sensor for ultrasonic power measurement
A polarimetric fiber-optic sensor using a polarization-maintaining fiber is described. The principle of the sensor is based on the detection of ultrasonically induced birefringence in the fiber. Its response to continuous and pulsed ultrasound at different frequencies and different power levels is investigated. The beam profiles measured by this sensor are compared with those measured using a PVDF (polyvinylidene fluoride) hydrophone. The sensor output is observed to be a linear function of the square root of the total acoustic power measured using a radiation force balance. The application of this sensor to the characterization of medical ultrasonic transducers is also discussed.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信