模块化长闪络对中压架空线路的防雷保护

G. V. Podporkin, V. Pilshikov, A. Sivaev
{"title":"模块化长闪络对中压架空线路的防雷保护","authors":"G. V. Podporkin, V. Pilshikov, A. Sivaev","doi":"10.1109/PESS.2002.1043226","DOIUrl":null,"url":null,"abstract":"Summary form only given, as follows. A long flashover arrester (LFA) which comprises three flashover modules using the creeping discharge effect is described in this paper. In this design, the total arrester-stressing voltage is applied simultaneously to all the modules so that the voltage-time characteristics of the arrester are improved considerably assuring reliable protection of medium voltage (e.g. 10 kV) overhead power lines against both induced overvoltages and direct lightning strokes. A single LFA per support or pole is found to be sufficient to protect an overhead line against induced overvoltages. An LFA should be arranged in parallel with each insulator in order to protect a line against direct lightning strokes.","PeriodicalId":117177,"journal":{"name":"IEEE Power Engineering Society Summer Meeting,","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Lightning protection of medium voltage overhead lines by modular long-flashover\",\"authors\":\"G. V. Podporkin, V. Pilshikov, A. Sivaev\",\"doi\":\"10.1109/PESS.2002.1043226\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Summary form only given, as follows. A long flashover arrester (LFA) which comprises three flashover modules using the creeping discharge effect is described in this paper. In this design, the total arrester-stressing voltage is applied simultaneously to all the modules so that the voltage-time characteristics of the arrester are improved considerably assuring reliable protection of medium voltage (e.g. 10 kV) overhead power lines against both induced overvoltages and direct lightning strokes. A single LFA per support or pole is found to be sufficient to protect an overhead line against induced overvoltages. An LFA should be arranged in parallel with each insulator in order to protect a line against direct lightning strokes.\",\"PeriodicalId\":117177,\"journal\":{\"name\":\"IEEE Power Engineering Society Summer Meeting,\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Power Engineering Society Summer Meeting,\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESS.2002.1043226\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Power Engineering Society Summer Meeting,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESS.2002.1043226","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

仅给出摘要形式,如下。介绍了一种利用蠕变放电效应,由三个闪络模块组成的长型闪络避雷器。在这种设计中,避雷器的总应力电压同时施加到所有模块上,因此避雷器的电压-时间特性得到了相当大的改善,确保了中压(例如10kv)架空电力线对感应过电压和直接雷击的可靠保护。每个支撑柱或电线杆一个LFA被发现足以保护架空线路免受感应过电压的影响。LFA应与每个绝缘子平行布置,以保护线路免受直击雷击。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Lightning protection of medium voltage overhead lines by modular long-flashover
Summary form only given, as follows. A long flashover arrester (LFA) which comprises three flashover modules using the creeping discharge effect is described in this paper. In this design, the total arrester-stressing voltage is applied simultaneously to all the modules so that the voltage-time characteristics of the arrester are improved considerably assuring reliable protection of medium voltage (e.g. 10 kV) overhead power lines against both induced overvoltages and direct lightning strokes. A single LFA per support or pole is found to be sufficient to protect an overhead line against induced overvoltages. An LFA should be arranged in parallel with each insulator in order to protect a line against direct lightning strokes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信