[2010]基于动态-静态的异构数据中心热感知方法

Marina Zapater, J. L. Risco-Martín, Z. Bankovic, J. Ayala, Jose M. Moya
{"title":"[2010]基于动态-静态的异构数据中心热感知方法","authors":"Marina Zapater, J. L. Risco-Martín, Z. Bankovic, J. Ayala, Jose M. Moya","doi":"10.1109/IWIA.2010.7","DOIUrl":null,"url":null,"abstract":"The thermal profile of data centers plays a significant role in affecting the cooling cost and power budget of the system. While several dynamic and static approaches have been proposed so far, these have failed on considering the whole picture. This paper proposes a combined static and dynamic approach that shows the benefits of the efficient scheduling strategies on leading to thermal-efficient floorplans. The devised methodology comes out with a placement of processors and task scheduling for a heterogeneous system, where the main thermal metrics (maximum temperature and thermal gradient) have been optimized.","PeriodicalId":339844,"journal":{"name":"2010 International Workshop on Innovative Architecture for Future Generation High Performance","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[2010] Combined Dynamic-Static Approach for Thermal-Awareness in Heterogeneous Data Centers\",\"authors\":\"Marina Zapater, J. L. Risco-Martín, Z. Bankovic, J. Ayala, Jose M. Moya\",\"doi\":\"10.1109/IWIA.2010.7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The thermal profile of data centers plays a significant role in affecting the cooling cost and power budget of the system. While several dynamic and static approaches have been proposed so far, these have failed on considering the whole picture. This paper proposes a combined static and dynamic approach that shows the benefits of the efficient scheduling strategies on leading to thermal-efficient floorplans. The devised methodology comes out with a placement of processors and task scheduling for a heterogeneous system, where the main thermal metrics (maximum temperature and thermal gradient) have been optimized.\",\"PeriodicalId\":339844,\"journal\":{\"name\":\"2010 International Workshop on Innovative Architecture for Future Generation High Performance\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Workshop on Innovative Architecture for Future Generation High Performance\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IWIA.2010.7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Workshop on Innovative Architecture for Future Generation High Performance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWIA.2010.7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

数据中心的热分布对系统的冷却成本和功耗预算有着重要的影响。虽然到目前为止已经提出了几种动态和静态方法,但这些方法都未能考虑到整体情况。本文提出了一种静态和动态相结合的方法,显示了高效调度策略在导致热效率平面图方面的好处。所设计的方法为异构系统提供了处理器的位置和任务调度,其中主要的热度量(最高温度和热梯度)已经优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[2010] Combined Dynamic-Static Approach for Thermal-Awareness in Heterogeneous Data Centers
The thermal profile of data centers plays a significant role in affecting the cooling cost and power budget of the system. While several dynamic and static approaches have been proposed so far, these have failed on considering the whole picture. This paper proposes a combined static and dynamic approach that shows the benefits of the efficient scheduling strategies on leading to thermal-efficient floorplans. The devised methodology comes out with a placement of processors and task scheduling for a heterogeneous system, where the main thermal metrics (maximum temperature and thermal gradient) have been optimized.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信