{"title":"三头伽玛相机针孔SPECT系统的仿真研究","authors":"Y. Ichimura, K. Ogawa","doi":"10.1109/NSSMIC.2014.7430822","DOIUrl":null,"url":null,"abstract":"The purpose of our research is to develop a new pinhole SPECT system using a triple head gamma camera system. The proposed data acquisition geometry used multi-pinhole collimators attached to each gamma camera. Acquired data were reconstructed with the OS-EM method. We evaluated the feasibility of the system with simulations. In the simulations, we evaluated three types of the pinhole collimators with the numbers of pinholes; 5, 8 and 11. And we used a brain phantom and myocardial phantom. Attenuation correction was conducted with the x-ray CT image of the corresponding slice. The results of the simulations confirmed the feasibility of our proposed multi-pinhole SPECT system with more than eight pinholes for each detector.","PeriodicalId":144711,"journal":{"name":"2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simulation study of a pinhole SPECT system with a triple head gamma camera\",\"authors\":\"Y. Ichimura, K. Ogawa\",\"doi\":\"10.1109/NSSMIC.2014.7430822\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of our research is to develop a new pinhole SPECT system using a triple head gamma camera system. The proposed data acquisition geometry used multi-pinhole collimators attached to each gamma camera. Acquired data were reconstructed with the OS-EM method. We evaluated the feasibility of the system with simulations. In the simulations, we evaluated three types of the pinhole collimators with the numbers of pinholes; 5, 8 and 11. And we used a brain phantom and myocardial phantom. Attenuation correction was conducted with the x-ray CT image of the corresponding slice. The results of the simulations confirmed the feasibility of our proposed multi-pinhole SPECT system with more than eight pinholes for each detector.\",\"PeriodicalId\":144711,\"journal\":{\"name\":\"2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2014.7430822\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2014.7430822","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们的研究目的是开发一种新的针孔SPECT系统,使用三头伽马相机系统。所提出的数据采集几何使用附加在每个伽马相机上的多针孔准直器。采集的数据用OS-EM方法进行重构。我们通过仿真来评估该系统的可行性。在模拟中,我们用针孔数对三种类型的针孔准直器进行了评价;5 8和11。我们用了脑模和心肌模。利用相应切片的x线CT图像进行衰减校正。仿真结果证实了我们提出的每个探测器有8个以上针孔的多针孔SPECT系统的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simulation study of a pinhole SPECT system with a triple head gamma camera
The purpose of our research is to develop a new pinhole SPECT system using a triple head gamma camera system. The proposed data acquisition geometry used multi-pinhole collimators attached to each gamma camera. Acquired data were reconstructed with the OS-EM method. We evaluated the feasibility of the system with simulations. In the simulations, we evaluated three types of the pinhole collimators with the numbers of pinholes; 5, 8 and 11. And we used a brain phantom and myocardial phantom. Attenuation correction was conducted with the x-ray CT image of the corresponding slice. The results of the simulations confirmed the feasibility of our proposed multi-pinhole SPECT system with more than eight pinholes for each detector.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信