{"title":"一种消除动态电压恢复器串联变压器直流磁通的实用方法","authors":"T. Jimichi, H. Fujita, H. Akagi","doi":"10.1109/PCCON.2007.373187","DOIUrl":null,"url":null,"abstract":"This paper proposes a control method for eliminating dc magnetic flux from the series transformer of a DVR. The method is characterized by intentionally injecting no compensating voltage during a one-sixth line cycle (=3.3 ms at 50 Hz). The control sequence is independent of an initial phase angle of a voltage sag, thus requiring no flux detection. The period, during which no compensating voltage is injected, is one-third as short as that of an existing method. This paper verifies the effectiveness and viability of the proposed method, using a 200-V, 5-kW laboratory system. The proposed method brings no dc magnetic flux to the series transformer.","PeriodicalId":325362,"journal":{"name":"2007 Power Conversion Conference - Nagoya","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A Practical Approach to Eliminating DC Magnetic Flux from the Series Transformer of a Dynamic Voltage Restorer\",\"authors\":\"T. Jimichi, H. Fujita, H. Akagi\",\"doi\":\"10.1109/PCCON.2007.373187\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a control method for eliminating dc magnetic flux from the series transformer of a DVR. The method is characterized by intentionally injecting no compensating voltage during a one-sixth line cycle (=3.3 ms at 50 Hz). The control sequence is independent of an initial phase angle of a voltage sag, thus requiring no flux detection. The period, during which no compensating voltage is injected, is one-third as short as that of an existing method. This paper verifies the effectiveness and viability of the proposed method, using a 200-V, 5-kW laboratory system. The proposed method brings no dc magnetic flux to the series transformer.\",\"PeriodicalId\":325362,\"journal\":{\"name\":\"2007 Power Conversion Conference - Nagoya\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-04-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 Power Conversion Conference - Nagoya\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCCON.2007.373187\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Power Conversion Conference - Nagoya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCCON.2007.373187","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Practical Approach to Eliminating DC Magnetic Flux from the Series Transformer of a Dynamic Voltage Restorer
This paper proposes a control method for eliminating dc magnetic flux from the series transformer of a DVR. The method is characterized by intentionally injecting no compensating voltage during a one-sixth line cycle (=3.3 ms at 50 Hz). The control sequence is independent of an initial phase angle of a voltage sag, thus requiring no flux detection. The period, during which no compensating voltage is injected, is one-third as short as that of an existing method. This paper verifies the effectiveness and viability of the proposed method, using a 200-V, 5-kW laboratory system. The proposed method brings no dc magnetic flux to the series transformer.