J. Pihera, P. Trnka, V. Mentlík, M. Širůček, P. Mráz
{"title":"有机油绝缘内的电晕放电","authors":"J. Pihera, P. Trnka, V. Mentlík, M. Širůček, P. Mráz","doi":"10.1109/ICDL.2011.6015412","DOIUrl":null,"url":null,"abstract":"Presented experiment consists of laboratory testing of partial discharges activity in liquid insulating fluids. Corona discharges within different insulation fluids were measured accordingly. The trends of partial discharge main parameters are studied and described in dependence on liquid type and aging time. The studied oils were thermally aged at 90°C for 3000 hours in air atmosphere within special climatic oven. Corona discharges measurement was realized using a point/plane electrode configuration where the whole test set-up was completely immersed in tested oil to suppress ambient conditions.","PeriodicalId":364451,"journal":{"name":"2011 IEEE International Conference on Dielectric Liquids","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Corona discharge within organic oil insulations\",\"authors\":\"J. Pihera, P. Trnka, V. Mentlík, M. Širůček, P. Mráz\",\"doi\":\"10.1109/ICDL.2011.6015412\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Presented experiment consists of laboratory testing of partial discharges activity in liquid insulating fluids. Corona discharges within different insulation fluids were measured accordingly. The trends of partial discharge main parameters are studied and described in dependence on liquid type and aging time. The studied oils were thermally aged at 90°C for 3000 hours in air atmosphere within special climatic oven. Corona discharges measurement was realized using a point/plane electrode configuration where the whole test set-up was completely immersed in tested oil to suppress ambient conditions.\",\"PeriodicalId\":364451,\"journal\":{\"name\":\"2011 IEEE International Conference on Dielectric Liquids\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE International Conference on Dielectric Liquids\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICDL.2011.6015412\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Conference on Dielectric Liquids","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDL.2011.6015412","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Presented experiment consists of laboratory testing of partial discharges activity in liquid insulating fluids. Corona discharges within different insulation fluids were measured accordingly. The trends of partial discharge main parameters are studied and described in dependence on liquid type and aging time. The studied oils were thermally aged at 90°C for 3000 hours in air atmosphere within special climatic oven. Corona discharges measurement was realized using a point/plane electrode configuration where the whole test set-up was completely immersed in tested oil to suppress ambient conditions.