{"title":"高分辨率综合后向散射在急性心肌缺血中的应用","authors":"B. Bijnens, M. Herregods, J. Nuyts, P. Suetens, F. Van de Werf","doi":"10.1109/ULTSYM.1995.495772","DOIUrl":null,"url":null,"abstract":"The value of high resolution integrated backscatter (IB) for use in myocardial tissue characterization during acute ischemia was examined. In closed chest dogs, myocardial ischemia was induced in a small region. Before and after 5, 30 and 60 minutes of occlusion, echocardiography was performed. High resolution digital radiofrequency (RF) data of the complete sectorscan, and of 2 consecutive heart cycles, were acquired using a new acquisition approach. A region of interest was drawn on each image in both the (normally perfused) septum and the (ischemic) posterior wall. IB and cyclic variation (CV) of IB was calculated. Values were expressed using a linear scale. We found a significant increase in mean IB after 5 min in the ischemic region compared to the normally perfused region in all experiments. This increase persisted during the 60 minutes of occlusion. Furthermore, an increase in CV was observed during ischemia. This is in contradiction to the findings of other groups. One of the explanations is that we don't express the values on a logarithmic scale (dB), We can state that comparing the mean IB from different regions within the myocardium can discriminate ischemia in a very early stage in a canine model. The value and the meaning of the change in CV of IB however is not straightforward and remains an issue for further investigation.","PeriodicalId":268177,"journal":{"name":"1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High resolution integrated backscatter in acute myocardial ischemia\",\"authors\":\"B. Bijnens, M. Herregods, J. Nuyts, P. Suetens, F. Van de Werf\",\"doi\":\"10.1109/ULTSYM.1995.495772\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The value of high resolution integrated backscatter (IB) for use in myocardial tissue characterization during acute ischemia was examined. In closed chest dogs, myocardial ischemia was induced in a small region. Before and after 5, 30 and 60 minutes of occlusion, echocardiography was performed. High resolution digital radiofrequency (RF) data of the complete sectorscan, and of 2 consecutive heart cycles, were acquired using a new acquisition approach. A region of interest was drawn on each image in both the (normally perfused) septum and the (ischemic) posterior wall. IB and cyclic variation (CV) of IB was calculated. Values were expressed using a linear scale. We found a significant increase in mean IB after 5 min in the ischemic region compared to the normally perfused region in all experiments. This increase persisted during the 60 minutes of occlusion. Furthermore, an increase in CV was observed during ischemia. This is in contradiction to the findings of other groups. One of the explanations is that we don't express the values on a logarithmic scale (dB), We can state that comparing the mean IB from different regions within the myocardium can discriminate ischemia in a very early stage in a canine model. The value and the meaning of the change in CV of IB however is not straightforward and remains an issue for further investigation.\",\"PeriodicalId\":268177,\"journal\":{\"name\":\"1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1995.495772\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1995.495772","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究了高分辨率综合后向散射(IB)在急性缺血心肌组织表征中的应用价值。闭胸犬在小范围内引起心肌缺血。阻断前后5、30、60分钟分别行超声心动图检查。使用一种新的采集方法获得了完整扇形扫描和连续2个心脏周期的高分辨率数字射频(RF)数据。在(正常灌注的)中隔和(缺血的)后壁的每幅图像上绘制一个感兴趣的区域。计算IB和循环变化(CV)。数值用线性刻度表示。我们发现,与正常灌注区相比,在所有实验中,缺血区5分钟后的平均IB显著增加。这种增加持续了60分钟的闭塞。此外,在缺血期间观察到CV升高。这与其他研究小组的发现相矛盾。其中一个解释是,我们没有在对数尺度(dB)上表示值,我们可以声明,比较心肌不同区域的平均IB可以在犬模型的早期阶段区分缺血。然而,IB CV变化的价值和意义并不简单,仍有待进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
High resolution integrated backscatter in acute myocardial ischemia
The value of high resolution integrated backscatter (IB) for use in myocardial tissue characterization during acute ischemia was examined. In closed chest dogs, myocardial ischemia was induced in a small region. Before and after 5, 30 and 60 minutes of occlusion, echocardiography was performed. High resolution digital radiofrequency (RF) data of the complete sectorscan, and of 2 consecutive heart cycles, were acquired using a new acquisition approach. A region of interest was drawn on each image in both the (normally perfused) septum and the (ischemic) posterior wall. IB and cyclic variation (CV) of IB was calculated. Values were expressed using a linear scale. We found a significant increase in mean IB after 5 min in the ischemic region compared to the normally perfused region in all experiments. This increase persisted during the 60 minutes of occlusion. Furthermore, an increase in CV was observed during ischemia. This is in contradiction to the findings of other groups. One of the explanations is that we don't express the values on a logarithmic scale (dB), We can state that comparing the mean IB from different regions within the myocardium can discriminate ischemia in a very early stage in a canine model. The value and the meaning of the change in CV of IB however is not straightforward and remains an issue for further investigation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信