{"title":"1.75 D超声阵列设计中的波束形成方案及参数权衡","authors":"Shikui Yan, P. Guo, Quing Zhu","doi":"10.1109/NEBC.2001.924720","DOIUrl":null,"url":null,"abstract":"A 1280-element, high resolution, ultrasound array transducer operating at 5 MHz has been constructed by Tetrad Inc. We are currently studying the beamforming schemes and parameter tradeoffs of this 1.75 D array system and will present our simulation results.","PeriodicalId":269364,"journal":{"name":"Proceedings of the IEEE 27th Annual Northeast Bioengineering Conference (Cat. No.01CH37201)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Beamforming scheme and parameter tradeoff in a 1.75 D ultrasound array design\",\"authors\":\"Shikui Yan, P. Guo, Quing Zhu\",\"doi\":\"10.1109/NEBC.2001.924720\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A 1280-element, high resolution, ultrasound array transducer operating at 5 MHz has been constructed by Tetrad Inc. We are currently studying the beamforming schemes and parameter tradeoffs of this 1.75 D array system and will present our simulation results.\",\"PeriodicalId\":269364,\"journal\":{\"name\":\"Proceedings of the IEEE 27th Annual Northeast Bioengineering Conference (Cat. No.01CH37201)\",\"volume\":\"47 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the IEEE 27th Annual Northeast Bioengineering Conference (Cat. No.01CH37201)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBC.2001.924720\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IEEE 27th Annual Northeast Bioengineering Conference (Cat. No.01CH37201)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBC.2001.924720","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Beamforming scheme and parameter tradeoff in a 1.75 D ultrasound array design
A 1280-element, high resolution, ultrasound array transducer operating at 5 MHz has been constructed by Tetrad Inc. We are currently studying the beamforming schemes and parameter tradeoffs of this 1.75 D array system and will present our simulation results.