{"title":"THOR任务电磁洁净度方法预验证的EMC评估","authors":"C. Capsalis, C. D. Nikolopoulos, S. Spantideas, A. T. Baklezos, E. G. Chatzineofytou, G. I. Koutantos, D. Boschetti, I. Marziali, M. Nicoletto, S. Tsatalas, K. Mehlem, A. Junge","doi":"10.23919/AeroEMC.2019.8788958","DOIUrl":null,"url":null,"abstract":"In this paper, an assessment of the measurement test results of the extremely low frequency (ELF) electromagnetic (EM) behaviour of several spacecraft units is demonstrated. The present work has been carried out in the framework of ESA's study Pre-Verification of THOR Electro-Magnetic Cleanliness Approach. The test measurement setups are discussed and analyzed, along with the THOR mission requirements of both electric and magnetic field emissions. Moreover, the test results are evaluated for both transient and steady state operation of typical spacecraft units. This investigation is an essential part of the EM cleanliness, since its outcomes may be used in the development of methods for prediction of unit level AC magnetic & electric fields.","PeriodicalId":436679,"journal":{"name":"2019 ESA Workshop on Aerospace EMC (Aerospace EMC)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"EMC Assessment for Pre-Verification of THOR Mission Electromagnetic Cleanliness Approach\",\"authors\":\"C. Capsalis, C. D. Nikolopoulos, S. Spantideas, A. T. Baklezos, E. G. Chatzineofytou, G. I. Koutantos, D. Boschetti, I. Marziali, M. Nicoletto, S. Tsatalas, K. Mehlem, A. Junge\",\"doi\":\"10.23919/AeroEMC.2019.8788958\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, an assessment of the measurement test results of the extremely low frequency (ELF) electromagnetic (EM) behaviour of several spacecraft units is demonstrated. The present work has been carried out in the framework of ESA's study Pre-Verification of THOR Electro-Magnetic Cleanliness Approach. The test measurement setups are discussed and analyzed, along with the THOR mission requirements of both electric and magnetic field emissions. Moreover, the test results are evaluated for both transient and steady state operation of typical spacecraft units. This investigation is an essential part of the EM cleanliness, since its outcomes may be used in the development of methods for prediction of unit level AC magnetic & electric fields.\",\"PeriodicalId\":436679,\"journal\":{\"name\":\"2019 ESA Workshop on Aerospace EMC (Aerospace EMC)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 ESA Workshop on Aerospace EMC (Aerospace EMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/AeroEMC.2019.8788958\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 ESA Workshop on Aerospace EMC (Aerospace EMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/AeroEMC.2019.8788958","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文对多个航天器单元的极低频电磁性能测试结果进行了评估。目前的工作是在欧空局研究THOR电磁清洁方法的预验证的框架下进行的。讨论和分析了测试测量设置,以及THOR任务对电场和磁场发射的要求。并对典型航天器单元的瞬态和稳态运行结果进行了评价。这项研究是电磁洁净度的重要组成部分,因为其结果可用于开发单位级交流磁场和电场的预测方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
EMC Assessment for Pre-Verification of THOR Mission Electromagnetic Cleanliness Approach
In this paper, an assessment of the measurement test results of the extremely low frequency (ELF) electromagnetic (EM) behaviour of several spacecraft units is demonstrated. The present work has been carried out in the framework of ESA's study Pre-Verification of THOR Electro-Magnetic Cleanliness Approach. The test measurement setups are discussed and analyzed, along with the THOR mission requirements of both electric and magnetic field emissions. Moreover, the test results are evaluated for both transient and steady state operation of typical spacecraft units. This investigation is an essential part of the EM cleanliness, since its outcomes may be used in the development of methods for prediction of unit level AC magnetic & electric fields.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信