一种瞬时无功功率补偿新方法

A. Zakeri, K. Kanz, M. Bina
{"title":"一种瞬时无功功率补偿新方法","authors":"A. Zakeri, K. Kanz, M. Bina","doi":"10.1109/IEMDC.2007.382739","DOIUrl":null,"url":null,"abstract":"The theory of the instantaneous three-phase powers have been developing in different ways. The zero sequence components of the load affect the source during the process of instantaneous inactive or reactive power compensation. Different approaches have been used to overcome this issue, such as Clark transformation to separate zero sequence components from the phase quantities. This paper introduces a new approach to a previously proposed theory of the instantaneous reactive power compensation, minimization method. The proposed method is applicable to all balanced three-phase systems as well as unbalanced system without zero sequence components. A separate paper discusses a new way of overcoming the effects of the zero sequence components on the source currents, extending the new approach to all unbalanced systems.","PeriodicalId":446844,"journal":{"name":"2007 IEEE International Electric Machines & Drives Conference","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"A New Approach to Compensation of Instantaneous Inactive Power\",\"authors\":\"A. Zakeri, K. Kanz, M. Bina\",\"doi\":\"10.1109/IEMDC.2007.382739\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The theory of the instantaneous three-phase powers have been developing in different ways. The zero sequence components of the load affect the source during the process of instantaneous inactive or reactive power compensation. Different approaches have been used to overcome this issue, such as Clark transformation to separate zero sequence components from the phase quantities. This paper introduces a new approach to a previously proposed theory of the instantaneous reactive power compensation, minimization method. The proposed method is applicable to all balanced three-phase systems as well as unbalanced system without zero sequence components. A separate paper discusses a new way of overcoming the effects of the zero sequence components on the source currents, extending the new approach to all unbalanced systems.\",\"PeriodicalId\":446844,\"journal\":{\"name\":\"2007 IEEE International Electric Machines & Drives Conference\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-05-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE International Electric Machines & Drives Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMDC.2007.382739\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE International Electric Machines & Drives Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMDC.2007.382739","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

瞬时三相电源理论一直在以不同的方式发展。在瞬时无功或无功补偿过程中,负载的零序分量会对电源产生影响。不同的方法已被用来克服这个问题,如克拉克变换分离零序分量从相位量。本文在已有的瞬时无功补偿理论的基础上提出了一种新的方法——最小化法。该方法适用于所有三相平衡系统和无零序分量的不平衡系统。另一篇论文讨论了一种克服零序分量对源电流影响的新方法,将新方法推广到所有不平衡系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A New Approach to Compensation of Instantaneous Inactive Power
The theory of the instantaneous three-phase powers have been developing in different ways. The zero sequence components of the load affect the source during the process of instantaneous inactive or reactive power compensation. Different approaches have been used to overcome this issue, such as Clark transformation to separate zero sequence components from the phase quantities. This paper introduces a new approach to a previously proposed theory of the instantaneous reactive power compensation, minimization method. The proposed method is applicable to all balanced three-phase systems as well as unbalanced system without zero sequence components. A separate paper discusses a new way of overcoming the effects of the zero sequence components on the source currents, extending the new approach to all unbalanced systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信