将控制系统可靠性纳入分布式发电配电系统主动管理

K. Ma, J. Mutale
{"title":"将控制系统可靠性纳入分布式发电配电系统主动管理","authors":"K. Ma, J. Mutale","doi":"10.1109/ISGTEUROPE.2010.5638897","DOIUrl":null,"url":null,"abstract":"Several factors affect the viability of Active Management (AM) schemes in distribution systems with distributed generation. One of the critical factors is the control system reliability. While a lot of work has been done on the technical and economic aspects of active distribution network management, almost no attention has been paid to the impact of the reliability of control and communication systems on the expected benefits of active management strategies. This paper investigates the impact of control system reliability on the benefits of AM. The reliability of the control system is assessed through a state enumeration approach, with different load levels. The results for the specific test case suggest that the load level and AM control system reliability should be jointly taken into account for a comprehensive analysis on the overall cost benefit of AM compared to Traditional Reinforcement Scheme (TRS), and that under each load level the economic benefit of AM improves with the improvement of AM control system reliability.","PeriodicalId":267185,"journal":{"name":"2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2010-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Incorporating control system reliability in active management of distribution systems with distributed generation\",\"authors\":\"K. Ma, J. Mutale\",\"doi\":\"10.1109/ISGTEUROPE.2010.5638897\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Several factors affect the viability of Active Management (AM) schemes in distribution systems with distributed generation. One of the critical factors is the control system reliability. While a lot of work has been done on the technical and economic aspects of active distribution network management, almost no attention has been paid to the impact of the reliability of control and communication systems on the expected benefits of active management strategies. This paper investigates the impact of control system reliability on the benefits of AM. The reliability of the control system is assessed through a state enumeration approach, with different load levels. The results for the specific test case suggest that the load level and AM control system reliability should be jointly taken into account for a comprehensive analysis on the overall cost benefit of AM compared to Traditional Reinforcement Scheme (TRS), and that under each load level the economic benefit of AM improves with the improvement of AM control system reliability.\",\"PeriodicalId\":267185,\"journal\":{\"name\":\"2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEUROPE.2010.5638897\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEUROPE.2010.5638897","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

影响分布式发电配电系统主动管理(AM)方案可行性的因素有很多。控制系统的可靠性是关键因素之一。虽然在主动配电网管理的技术和经济方面已经做了大量的工作,但几乎没有注意到控制和通信系统的可靠性对主动管理策略预期效益的影响。本文研究了控制系统可靠性对增材制造效益的影响。采用状态枚举法对不同负荷水平下控制系统的可靠性进行了评估。具体试验案例的结果表明,与传统加固方案(TRS)相比,应综合考虑负荷水平和调幅控制系统可靠性,综合分析调幅的总体成本效益,在各负荷水平下,随着调幅控制系统可靠性的提高,调幅的经济效益也随之提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Incorporating control system reliability in active management of distribution systems with distributed generation
Several factors affect the viability of Active Management (AM) schemes in distribution systems with distributed generation. One of the critical factors is the control system reliability. While a lot of work has been done on the technical and economic aspects of active distribution network management, almost no attention has been paid to the impact of the reliability of control and communication systems on the expected benefits of active management strategies. This paper investigates the impact of control system reliability on the benefits of AM. The reliability of the control system is assessed through a state enumeration approach, with different load levels. The results for the specific test case suggest that the load level and AM control system reliability should be jointly taken into account for a comprehensive analysis on the overall cost benefit of AM compared to Traditional Reinforcement Scheme (TRS), and that under each load level the economic benefit of AM improves with the improvement of AM control system reliability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信