M. Aoki, Yuta Kobayashi, Hiroshi Kobayashi, F. Ueda
{"title":"混合型电能质量调节器的静态电容控制","authors":"M. Aoki, Yuta Kobayashi, Hiroshi Kobayashi, F. Ueda","doi":"10.1109/TD-ASIA.2009.5356976","DOIUrl":null,"url":null,"abstract":"In recent years, the voltage rise at the end of distribution line and the increase of harmonic voltages has become to be greatly concerned because of extreme expansion of distributed generation (DG) systems and excessive amount of static capacitors (SCs) for improving power factor. For compensating leading current and harmonic currents from consumers, the hybrid type of power quality conditioner was proposed. The proposed system consists of a LC series circuit, a series transformer and a self-commutated converter in order to reduce the capacity of the converter than the conventional type of static synchronous compensators (STATCOMs) and active filters (AFs). This paper presents SC bank quantity control to expand the range of the compensating current and DC bus voltage control of the converter in the hybrid type power quality conditioner. In this study, the performance evaluations for the proposed conditioner in terms of the control of the harmful currents are presented by the various simulations.","PeriodicalId":131589,"journal":{"name":"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific","volume":"106 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Static capacitor control for hybrid type power quality conditioner\",\"authors\":\"M. Aoki, Yuta Kobayashi, Hiroshi Kobayashi, F. Ueda\",\"doi\":\"10.1109/TD-ASIA.2009.5356976\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In recent years, the voltage rise at the end of distribution line and the increase of harmonic voltages has become to be greatly concerned because of extreme expansion of distributed generation (DG) systems and excessive amount of static capacitors (SCs) for improving power factor. For compensating leading current and harmonic currents from consumers, the hybrid type of power quality conditioner was proposed. The proposed system consists of a LC series circuit, a series transformer and a self-commutated converter in order to reduce the capacity of the converter than the conventional type of static synchronous compensators (STATCOMs) and active filters (AFs). This paper presents SC bank quantity control to expand the range of the compensating current and DC bus voltage control of the converter in the hybrid type power quality conditioner. In this study, the performance evaluations for the proposed conditioner in terms of the control of the harmful currents are presented by the various simulations.\",\"PeriodicalId\":131589,\"journal\":{\"name\":\"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific\",\"volume\":\"106 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TD-ASIA.2009.5356976\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TD-ASIA.2009.5356976","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

近年来,由于分布式发电系统的过度扩张和为提高功率因数而使用过多的静态电容器,导致配电线路末端电压升高和谐波电压升高成为人们关注的问题。为了补偿超前电流和用户谐波电流,提出了混合型电能质量调节器。该系统由LC串联电路、串联变压器和自整流变换器组成,以减少变换器的容量,而不是传统类型的静态同步补偿器(STATCOMs)和有源滤波器(AFs)。在混合型电能质量调节器中,采用SC组数量控制来扩大补偿电流的范围,并对变换器的直流母线电压进行控制。在本研究中,通过各种模拟,对所提出的调节器在控制有害电流方面的性能进行了评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Static capacitor control for hybrid type power quality conditioner
In recent years, the voltage rise at the end of distribution line and the increase of harmonic voltages has become to be greatly concerned because of extreme expansion of distributed generation (DG) systems and excessive amount of static capacitors (SCs) for improving power factor. For compensating leading current and harmonic currents from consumers, the hybrid type of power quality conditioner was proposed. The proposed system consists of a LC series circuit, a series transformer and a self-commutated converter in order to reduce the capacity of the converter than the conventional type of static synchronous compensators (STATCOMs) and active filters (AFs). This paper presents SC bank quantity control to expand the range of the compensating current and DC bus voltage control of the converter in the hybrid type power quality conditioner. In this study, the performance evaluations for the proposed conditioner in terms of the control of the harmful currents are presented by the various simulations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信