R. Mazlan, J. Kei, L. Hickson, S. Curtain, Gillian Baker, Kate E. Jarman, H. Glyde, J. Gavranich, Ron Linning
{"title":"6周龄健康婴儿声反射试验的重测信度","authors":"R. Mazlan, J. Kei, L. Hickson, S. Curtain, Gillian Baker, Kate E. Jarman, H. Glyde, J. Gavranich, Ron Linning","doi":"10.1375/AUDI.31.1.25","DOIUrl":null,"url":null,"abstract":"The aim of this study was to investigate the test-retest reliability of acoustic reflex (AR) test measured from a group of 6-week-old infants who passed a transient evoked otoacoustic emission test and an automated auditory brainstem response screening test. Ipsilateral acoustic reflex thresholds for a 2 kHz pure tone and broadband noise were recorded from 70 infants using a Madsen Otoflex Diagnostic Immittance meter with a probe tone of 1000 Hz. The mean AR thresholds obtained in the first test were 67.3 and 80.9 dB HL for the broadband noise and 2 kHz tone, respectively. The results for the retest condition did not differ significantly from those of the first test. The AR test also showed high test-retest reliability as demonstrated by intracorrelation coefficients across the test-retest conditions of 0.783 and 0.780 for the broadband noise and 2 kHz pure tone stimuli, respectively. Findings from this study suggest that the AR test could be used to establish reliable AR thresholds in 6-week-old infants.","PeriodicalId":114768,"journal":{"name":"Australian and New Zealand Journal of Audiology","volume":"97 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Test-retest reliability of acoustic reflex test in 6-Week-Old healthy infants\",\"authors\":\"R. Mazlan, J. Kei, L. Hickson, S. Curtain, Gillian Baker, Kate E. Jarman, H. Glyde, J. Gavranich, Ron Linning\",\"doi\":\"10.1375/AUDI.31.1.25\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this study was to investigate the test-retest reliability of acoustic reflex (AR) test measured from a group of 6-week-old infants who passed a transient evoked otoacoustic emission test and an automated auditory brainstem response screening test. Ipsilateral acoustic reflex thresholds for a 2 kHz pure tone and broadband noise were recorded from 70 infants using a Madsen Otoflex Diagnostic Immittance meter with a probe tone of 1000 Hz. The mean AR thresholds obtained in the first test were 67.3 and 80.9 dB HL for the broadband noise and 2 kHz tone, respectively. The results for the retest condition did not differ significantly from those of the first test. The AR test also showed high test-retest reliability as demonstrated by intracorrelation coefficients across the test-retest conditions of 0.783 and 0.780 for the broadband noise and 2 kHz pure tone stimuli, respectively. Findings from this study suggest that the AR test could be used to establish reliable AR thresholds in 6-week-old infants.\",\"PeriodicalId\":114768,\"journal\":{\"name\":\"Australian and New Zealand Journal of Audiology\",\"volume\":\"97 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Australian and New Zealand Journal of Audiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1375/AUDI.31.1.25\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australian and New Zealand Journal of Audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1375/AUDI.31.1.25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
本研究的目的是探讨6周大的婴儿通过瞬态诱发耳声发射测试和自动听觉脑干反应筛选测试所测得的声反射(AR)测试的重测信度。使用探测音调为1000 Hz的Madsen Otoflex诊断阻抗计记录了70名婴儿的2 kHz纯音和宽带噪声的同侧声反射阈值。在第一次测试中获得的宽带噪声和2 kHz音调的平均AR阈值分别为67.3和80.9 dB HL。复测条件的结果与第一次试验的结果没有显著差异。宽带噪声和2 kHz纯音刺激的内相关系数分别为0.783和0.780,表明AR测试也显示出较高的重测信度。本研究结果表明,AR测试可用于建立可靠的6周大婴儿AR阈值。
Test-retest reliability of acoustic reflex test in 6-Week-Old healthy infants
The aim of this study was to investigate the test-retest reliability of acoustic reflex (AR) test measured from a group of 6-week-old infants who passed a transient evoked otoacoustic emission test and an automated auditory brainstem response screening test. Ipsilateral acoustic reflex thresholds for a 2 kHz pure tone and broadband noise were recorded from 70 infants using a Madsen Otoflex Diagnostic Immittance meter with a probe tone of 1000 Hz. The mean AR thresholds obtained in the first test were 67.3 and 80.9 dB HL for the broadband noise and 2 kHz tone, respectively. The results for the retest condition did not differ significantly from those of the first test. The AR test also showed high test-retest reliability as demonstrated by intracorrelation coefficients across the test-retest conditions of 0.783 and 0.780 for the broadband noise and 2 kHz pure tone stimuli, respectively. Findings from this study suggest that the AR test could be used to establish reliable AR thresholds in 6-week-old infants.