{"title":"利用电机电流特征分析和电机杂散磁通分析变频异步电机气隙偏心","authors":"I. Chernyavska, O. Vitek","doi":"10.1109/DEMPED.2017.8062336","DOIUrl":null,"url":null,"abstract":"In this paper the analysis of effect of eccentricity fault in squirrel-cage induction motor fed by frequency converter is presented. The motor current signature analysis as well as stray flux of motor were used in order to verify the capability of these techniques to identify the presence of different types of eccentricity fault in case of different types of supply. There were measured 4-pole and 6-pole motors. Obtained data is presented in the form of graphs and tables and the comparison of obtained results was carried out.","PeriodicalId":325413,"journal":{"name":"2017 IEEE 11th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"Analysis of air-gap eccentricity in inverter fed induction motor by means of motor current signature analysis and stray flux of motor\",\"authors\":\"I. Chernyavska, O. Vitek\",\"doi\":\"10.1109/DEMPED.2017.8062336\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper the analysis of effect of eccentricity fault in squirrel-cage induction motor fed by frequency converter is presented. The motor current signature analysis as well as stray flux of motor were used in order to verify the capability of these techniques to identify the presence of different types of eccentricity fault in case of different types of supply. There were measured 4-pole and 6-pole motors. Obtained data is presented in the form of graphs and tables and the comparison of obtained results was carried out.\",\"PeriodicalId\":325413,\"journal\":{\"name\":\"2017 IEEE 11th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)\",\"volume\":\"76 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE 11th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEMPED.2017.8062336\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 11th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEMPED.2017.8062336","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of air-gap eccentricity in inverter fed induction motor by means of motor current signature analysis and stray flux of motor
In this paper the analysis of effect of eccentricity fault in squirrel-cage induction motor fed by frequency converter is presented. The motor current signature analysis as well as stray flux of motor were used in order to verify the capability of these techniques to identify the presence of different types of eccentricity fault in case of different types of supply. There were measured 4-pole and 6-pole motors. Obtained data is presented in the form of graphs and tables and the comparison of obtained results was carried out.