弱母线多准则综合电压稳定指标识别

Peng Gao, Libao Shi, L. Yao, Y. Ni, M. Bazargan
{"title":"弱母线多准则综合电压稳定指标识别","authors":"Peng Gao, Libao Shi, L. Yao, Y. Ni, M. Bazargan","doi":"10.1109/TD-ASIA.2009.5356950","DOIUrl":null,"url":null,"abstract":"How to identify the weak buses comprehensively and practically in power system voltage stability analysis is an important issue, and is posing great interests to the power engineers. In this paper, a multi-criteria integrated voltage stability index was proposed for weak buses identification. Firstly, the bus voltage change index and reactive power margins, which were determined by P-V curve and Q-V curve, respectively, were employed to form the required data set involving the corresponding bus voltage margin and reactive power margin information. An overall and practical evaluation method called as ideal point method was then proposed to integrate the two aforementioned voltage stability indices with certain weight. By tuning the corresponding weight coefficients, the decision-making reflecting the preference of power engineer could be made. Finally the case studies on the 10-machine 39-bus New England test system as benchmark were carried out to demonstrate the validity and effectiveness of the proposed method.","PeriodicalId":131589,"journal":{"name":"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":"{\"title\":\"Multi-criteria integrated voltage stability index for weak buses identification\",\"authors\":\"Peng Gao, Libao Shi, L. Yao, Y. Ni, M. Bazargan\",\"doi\":\"10.1109/TD-ASIA.2009.5356950\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"How to identify the weak buses comprehensively and practically in power system voltage stability analysis is an important issue, and is posing great interests to the power engineers. In this paper, a multi-criteria integrated voltage stability index was proposed for weak buses identification. Firstly, the bus voltage change index and reactive power margins, which were determined by P-V curve and Q-V curve, respectively, were employed to form the required data set involving the corresponding bus voltage margin and reactive power margin information. An overall and practical evaluation method called as ideal point method was then proposed to integrate the two aforementioned voltage stability indices with certain weight. By tuning the corresponding weight coefficients, the decision-making reflecting the preference of power engineer could be made. Finally the case studies on the 10-machine 39-bus New England test system as benchmark were carried out to demonstrate the validity and effectiveness of the proposed method.\",\"PeriodicalId\":131589,\"journal\":{\"name\":\"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TD-ASIA.2009.5356950\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TD-ASIA.2009.5356950","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

摘要

在电力系统电压稳定分析中,如何全面、实用地识别弱母线是一个重要的问题,也是电力工程师非常感兴趣的问题。本文提出了一种多准则综合电压稳定指标,用于弱母线识别。首先,利用分别由P-V曲线和Q-V曲线确定的母线电压变化指数和无功裕度,形成包含相应母线电压裕度和无功裕度信息的所需数据集。在此基础上,提出了一种全面实用的评价方法——理想点法,将上述两个电压稳定指标以一定的权重进行综合。通过调整相应的权重系数,可以做出反映电力工程师偏好的决策。最后以10机39总线新英格兰测试系统为例,验证了所提方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multi-criteria integrated voltage stability index for weak buses identification
How to identify the weak buses comprehensively and practically in power system voltage stability analysis is an important issue, and is posing great interests to the power engineers. In this paper, a multi-criteria integrated voltage stability index was proposed for weak buses identification. Firstly, the bus voltage change index and reactive power margins, which were determined by P-V curve and Q-V curve, respectively, were employed to form the required data set involving the corresponding bus voltage margin and reactive power margin information. An overall and practical evaluation method called as ideal point method was then proposed to integrate the two aforementioned voltage stability indices with certain weight. By tuning the corresponding weight coefficients, the decision-making reflecting the preference of power engineer could be made. Finally the case studies on the 10-machine 39-bus New England test system as benchmark were carried out to demonstrate the validity and effectiveness of the proposed method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信