{"title":"采用新型50 GHz频段TM010模腔测量低损耗介质杆的复介电常数","authors":"Takashi Shimizu, Hikaru Inada, Y. Kogami","doi":"10.1109/ARFTG.2017.8000840","DOIUrl":null,"url":null,"abstract":"Complex permittivity of a low loss dielectric rod are often evaluated by a perturbation method using a TM010 mode cavity in microwave region, since the method is an extremely simple and easy treatment for not only experts but also non-experts. However, there are few reported to apply the perturbation method using millimeter wave band because a cavity dimension of the scale model is too small and is not realistic for material evaluation. In this paper, a simple and easy measurement technique for a dielectric rod is proposed using novel 50-GHz band TM010 cavities based on an improved perturbation method. The measured results validate the accuracy and the usefulness for the proposed method and cavity.","PeriodicalId":282023,"journal":{"name":"2017 89th ARFTG Microwave Measurement Conference (ARFTG)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Complex permittivity measurement for a low loss dielectric rod using a novel 50 GHz band TM010 mode cavity\",\"authors\":\"Takashi Shimizu, Hikaru Inada, Y. Kogami\",\"doi\":\"10.1109/ARFTG.2017.8000840\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Complex permittivity of a low loss dielectric rod are often evaluated by a perturbation method using a TM010 mode cavity in microwave region, since the method is an extremely simple and easy treatment for not only experts but also non-experts. However, there are few reported to apply the perturbation method using millimeter wave band because a cavity dimension of the scale model is too small and is not realistic for material evaluation. In this paper, a simple and easy measurement technique for a dielectric rod is proposed using novel 50-GHz band TM010 cavities based on an improved perturbation method. The measured results validate the accuracy and the usefulness for the proposed method and cavity.\",\"PeriodicalId\":282023,\"journal\":{\"name\":\"2017 89th ARFTG Microwave Measurement Conference (ARFTG)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 89th ARFTG Microwave Measurement Conference (ARFTG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ARFTG.2017.8000840\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 89th ARFTG Microwave Measurement Conference (ARFTG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG.2017.8000840","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Complex permittivity measurement for a low loss dielectric rod using a novel 50 GHz band TM010 mode cavity
Complex permittivity of a low loss dielectric rod are often evaluated by a perturbation method using a TM010 mode cavity in microwave region, since the method is an extremely simple and easy treatment for not only experts but also non-experts. However, there are few reported to apply the perturbation method using millimeter wave band because a cavity dimension of the scale model is too small and is not realistic for material evaluation. In this paper, a simple and easy measurement technique for a dielectric rod is proposed using novel 50-GHz band TM010 cavities based on an improved perturbation method. The measured results validate the accuracy and the usefulness for the proposed method and cavity.